Brochure/Catalogue

1.
Power supply
2.
Hazard warning device (Input),
Alarm (Output)
Risks such as break-ins, hold-ups and res constitute threats to
life, property and buildings. The early detection of emergency
situations requires non uninterruptible alarm systems. A reliable
power supply is crucial in avoiding hazardous breaches of
security.
Our OMNIMATE Signal series of PCB plug-in connectors provides
you with more than security. Our BLZP 5.0x scores particularly
highly with the following customer benets:
Secure conductor clamping thanks to its proven clamping
yoke system made from hardened steel and high-strength
clamping screws that pull the conductor against the busbar
and x it in the contact point
No need to carry out maintenance tasks in the long run due
to integral vibration protection
Fast, cost-efcient connecting due to fully open clamping
points ("Wire Ready")
Secure, error-free wiring thanks to integral
protection against the underinsertion of wire ("Wire Guard")
Can be used around the world due to universal screw head
(plus/minus screw)
Our wide range of OMNIMATE Signal series products is sure to
have the right solution for every requirement.
So you can be absolutely certain of the power supply!
To ensure that condential information or potentially
hazardous areas are only accessible to selected employees,
security systems control access. A huge amount of damage
can occur if unauthorised persons gain access to sensitive
areas. This underlines the importance of a properly
functioning access control system.
Our reow-compatible RJ45 solder sockets, for example,
which have been developed and tested according to high
security standards, ensure optimum signal transmission via
the data bus between sensors, the control centre and
actuators. Even high data rates (such as those needed for
video surveillance) or harsh environments in the eld do not
impair their reliability. This means that RJ45 connection
components full the highest requirements.
Variants for SMD or THR soldering methods
Optimum adaptation to housing designs due to variable
outlet directions (90°, 180°, 270°)
High electromagnetic compatibility and protection in
harsh conditions in the eld for secure data transmission
Future-proof thanks to Cat. 5 and Cat. 6
If you transfer signals via single wire, our LSF-SMD PUSH IN
PCB terminal is the right product for you.
Our optional marking service also ensures additional security
in your application. Coloured connection markings ensure
the error-free wiring of all our OMNIMATE Signal equipment
connection components.
While hazard warning devices detect potential threats and
make an emergency call where necessary, alarm systems
draw attention to the danger by means of visual and audible
signals. In order to ensure correct functionality, equipment
such as sophisticated camera systems require secure and
fault-free data transmission from the hazard warning device to
the alarm control centre. This saves lives in the event of an
emergency.
For reliable single-wire data transmission in the alarm chain,
our reow-compatible OMNIMATE LSF-SMD PUSH IN PCB
terminals can be easily ntegrated into all conventional
production processes in the industrial environment.
Design freedom for your equipment thanks to versatile
pitch sizes (3.50, 5.00, 7.50 mm) and wire outlet
directions (90°, 135°, 180°)
Specially designed for the SMD reow method
High-quality soldering due to coplanarity of max. 100 µm
Outstanding mechanical stability thanks to signicantly
higher axial tensile forces per pole than specied by
IEC 60947-7-4 and thanks to holding forces of more than
150 N per pole in the axial direction
Tested vibration and shock resistance in accordance with
IEC 61373/10.201 for smooth and long-term
maintenance-free operation
Our solderable RJ45 reow solder socket, however, is used
for eld communication via the data bus.
LSF-SMD PUSH IN PCB terminals and RJ45 solder sockets
are suitable for automatic assembly and provide cost savings
in PCB assembly of up to 30 %.
3.
Access control
OMNIMATE Signal BLZP 5.08 female plug with clamping-yoke screw connection OMNIMATE Signal LSF-SMD PCB terminals with spring connection using PUSH IN direct insertion
2. + 3.
Hazard warning device,
Alarm and Access control
1.
2. + 3.
Power supply
Hazard warning
device, Alarm and
Access control
1. Power supply
OMNIMATE Signal PCB terminals
LM, LSF-SMD, LSF-SMT, LL 5.0x
OMNIMATE Signal plug-in connectors
BLZP 5.0x, SL-SMT 5.0x, SL 5.0x
2. Hazard warning device (input),
Alarm (output)
OMNIMATE Signal PCB terminals
LSF-SMD, LSF-SMT, LM, PM, PS
OMNIMATE Signal plug-in connectors
BL 3.5, BC 3.81, B2CF, BLZP
RJ45 PCB sockets
IE-PCB-RJ45-SMD-C5-A
3. Access control
OMNIMATE Signal PCB terminals
LSF-SMD, LSF-SMT, LM, PM, PS
OMNIMATE Signal plug-in connectors
BL 3.5, BC 3.81, B2CF, BLZP
RJ45 PCB sockets
IE-PCB-RJ45-SMD-C5-A
Would you like more detailed
information?
Enter the search terms below in our online catalogue at:
http://catalog.weidmueller.com
RJ45 PCB sockets in IP 20 for copper and bre-optic cables
Our online product assistant
is also available for
accurate conguration:
http://galaxy.weidmueller.com