IP protection class
Electrical devices that are intended for use in industrial environments are
subjected to inuences other than household appliances.
The following table shows the protection classes with the associated limit values.
The protection classes are dened in the IP standard, DIN EN 60529: protection
degree provided by housing (IP code).
Table 2.1: Protection degrees against solid foreign matter
Code number Term - explanation
0 Notprotected
1 Protected against solid foreign matter, 50 mm diameter and larger
2
Protected against solid foreign matter, 12.5 mm diameter and larger
Example:theairslotsinaPCpower-supply-unithousing.
3 Protected against solid foreign matter, 2.5 mm diameter
4 Protected against solid foreign matter, 1 mm and larger
5
Dust-protected:
Penetrationofdustisnotcompletelyprevented,butdustmaynotpenetratetosuchanextentthattheopera-
tion of the device or the safety is impaired.
6
Dust-tight:
Nopenetrationofdustatapressureofunder20mbarinthehousing
Table 2.2: Protection degrees against water
2. Code number Term - explanation
0 Noprotection
1 Protectedagainstdrippingwater:verticallyfallingdropsmaynothaveanydamagingeffects.
2 Protectionagainstdrippingwater,whenthehousingisinclinedbyupto15°
3
Protectedagainstspray-water:waterthatissprayedatanangleofupto60°onbothsidesofthevertical
may not have any damaging effects.
4
Protectionagainstsplashingwater:
Water that is splashed from every direction against the housing may not have any damaging effects.
5
Protectionagainstwaterjets:
Water that is directed as jets from every direction against the housing may not have any damaging effects.
Note:correspondstoapprox.12.5litres/minute(gardenhose)Testperiodapprox.5minutes(allinformationsubject
tocorrection).
6
Protectionagainststrongwaterjets:
Water that is directed from every direction as strong jets against the housing may not have any damaging
effects.
7 Protectionagainsttheeffectsofbeingtemporarilysubmersedinwater
8
Protectedagainsttheeffectsofbeingsubmersedinwaterforalongperiodoftime.Anadditionalspecied
number indicates the submersion depth.