Brochure/Catalogue
B
B.112690170000
Honeywell C300 - FTA C300
Isolated input interface for digital cards
Passive interfaces (FTA) for connecting to Honeywell C300
analogue IOTAs.
• Clear identification: same connector and position on the
FTA and on the IOTA
• Reinforced insulation at input/output (basic between
contacts)
• Possibility of powering the IOTA from the FTA
• Screw or tension clamp connection
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Nominal output data
Contact material
Operating voltage
Max. DC continuous current
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min./max. (field)
Clamping range, min./max. (supply)
Rail
Length x width
Note
Ordering data
Screw connection
Note
Accessories
Note
FTA-C300-32DI-24 V DC
For: CC-TDIL01, CC-TDIL11
SLDV-THR 5.08
64-pole
RSS
green
yellow
No
630 mA
24 V DC ± 10%
13 mA
24 V DC ± 10%
AgNi gold flashed
24 V DC ± 10%
0.1 A
-25...50 °C
-40...60 °C
CE; EAC
< 50 V AC
< 50 V AC
III
III
2
1.5 kV
0.35 kVAC
≥ 6 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 35, TS 32
244 mm / 131 mm
Type Height Order No.
FTA-C300-32DI-24VDC-S 65 mm 1312040000
Relay 4061590000 RSS 24 V DC 1 CO AU
Dedicated solution for Honeywell C300