Hard Disk Drive Specification
Write Log Ext (3Fh)
Command Block Output Registers
Command Block Input Registers
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data Low
-
-
-
-
-
-
-
-
Data Low
-
-
-
-
-
-
-
-
Data High
-
-
-
-
-
-
-
-
Data High
-
-
-
-
-
-
-
-
Feature
Current
-
-
-
-
-
-
-
-
Error
…See Below…
Previous
-
-
-
-
-
-
-
-
Sector Count
Current
V
V
V
V
V
V
V
V
Sector Count
HOB=0
-
-
-
-
-
-
-
-
Previous
V
V
V
V
V
V
V
V
HOB=1
-
-
-
-
-
-
-
-
Sector Number
Current
V
V
V
V
V
V
V
V
Sector Number
HOB=0
-
-
-
-
-
-
-
-
Previous
-
-
-
-
-
-
-
-
HOB=1
-
-
-
-
-
-
-
-
Cylinder Low
Current
V
V
V
V
V
V
V
V
Cylinder Low
HOB=0
-
-
-
-
-
-
-
-
Previous
V
V
V
V
V
V
V
V
HOB=1
-
-
-
-
-
-
-
-
Cylinder High
Current
-
-
-
-
-
-
-
-
Cylinder High
HOB=0
-
-
-
-
-
-
-
-
Previous
-
-
-
-
-
-
-
-
HOB=1
-
-
-
-
-
-
-
-
Device/Head
1
-
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-
Command
0
0
1
1
1
1
1
1
Status
…See Below…
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY
RDY
DF
DSC
DRQ
COR
IDX
ERR
0
V
0
V
0
V
0
0
0
V
0
V
-
0
-
V
Table 256 Write Log Ext Command (3Fh)
This command writes a specified number of 512 byte data sectors to the specific log. The device shall interrupt for
each DRQ block transferred.
Output Parameters To The Device
Sector Count Current
The number of sectors to be written to the specified log low order, bits (7:0).
Sector Count Previous
The number of sectors to be written to the specified log high orders, bits (15:8). If the
number of sectors is greater than the number indicated in the Log directory, which is
available in Log number zero, the device shall return command aborted. The log
transferred to the device shall be stored by the device starting at the first sector in
the specified log.
Sector Number Current
The log to be written as described in Table 141 Log address definition. If the host
attempts to write to a read only log address, the device shall return command
aborted.
Cylinder Low Current
The first sector of the log to be written low order, bits (7:0).
Cylinder Low Previous
The first sector of the log to be written high order, bits (15:8).
If the feature set associated with the log specified in the Sector Number register is not supported or enabled, or if
the values in the Sector Count, Sector Number or Cylinder Low registers are invalid, the device shall return
command aborted. If the host attempts to write to a read only log address, the device shall return command
aborted.