Installation Instructions

Submersible Utility
Pump
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.
© 2000 Wayne Water Systems
Operating Instructions and Parts Manual TSC
Do not pump flammable or
explosive fluids such as gaso-
line, fuel oil, kerosene, etc. Do not use
in a flammable and/or explosive envi-
ronment. Pump only clear water.
Personal injury and/or property dam-
age will result.
Risk of electric shock! This
pump has not been tested for
use in swimming pool areas. Never
place pump in pools while people are
in the water.
Do not handle pump with wet
hands or when standing in
water or on a damp surface.
Risk of electric shock! This
pump is supplied with a
grounding conductor and grounding
type attachment plug. Use a grounded
receptacle to reduce the risk of fatal
electrical shock.
This pump con-
tains dielectric
motor oil for motor heat transfer.
Care should be taken when disposing
of this oil. Do not use this pump in
ponds or fountains because the motor
oil can be harmful to aquatic life.
2. Wear safety glasses at all
times when working with
pumps.
3. It is strongly recommended
that this unit be plugged into a
Ground Fault Circuit Interrupter
(GFCI). Consult a local electrician
for installation and availability.
4. Do not use the power cord or dis-
charge hose to carry or handle the
pump. Damage to the power cord
or discharge hose may occur. Use
the lifting ring supplied on the
pump.
!
WARNING
!
DANGER
!
DANGER
!
DANGER
!
DANGER
351301-001 1/00
Installation and Operation
Always disconnect
electric supply
before attempting to
install, service, relocate or perform any
maintenance. If the power source is
out of sight, lock and TAG IN OPEN
(OFF) POSITION to prevent unexpected
power application. Failure to do so
could result in fatal electrical shock!
This unit is not designed for
use in septic tanks or under-
ground vaults to pump raw sewage or
effluents. Never use in hazardous or
explosive locations.
1. This pump has been designed to
attach to a standard garden hose.
Thread the female end of the gar-
den hose to the male discharge on
the pump.
2. To reduce leakage between the
pump and the hose, place a hose
washer (not included) on the gar-
den hose before installing to the
pump.
3. For best pump performance,
unwind the hose before starting the
pump. This will help remove any
kinks or binds in the hose and allow
the unit to pump with less
restriction.
4. Set the pump on a hard surface in
the water. Do not set the pump
directly on mud or sand surfaces.
This will cause the inlet screen to
clog.
5. The water level must be at least 1/2
inches for the pump to operate.
Water levels less than 1/2 inches will
not allow the impeller to contact
water and no water will be
pumped.
!
NOTICE
!
DANGER
Description
This portable, submersible utility pump
is designed for non-automatic use in
water. The units are equipped with an
8 ft. 3-prong grounding type power
cord. The motor is oil filled and sealed
for cooler operation. The discharge fit-
ting is designed for convenient attach-
ment to a garden hose.
IMPORTANT: THIS PUMP IS NOT
SUITABLE FOR AQUATIC LIFE!
Unpacking
After unpacking the unit, carefully
inspect for any damage that may have
occurred during transit. Check for
loose, missing or damaged parts.
Danger indicates
an imminently haz-
ardous situation which, if not avoided,
WILL result in death or serious injury.
Warning indicates
a potentially haz-
ardous situation which, if not avoided,
COULD result in death or serious injury.
Caution indicates a
potentially haz-
ardous situation which, if not avoided,
MAY result in minor or moderate
injury.
Notice indicates
important informa-
tion, that if not followed, MAY cause
damage to equipment.
This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following:
1. Read these rules and
instructions carefully.
Failure to follow these
instructions could cause
serious bodily injury and/or proper-
ty damage.
!
NOTICE
!
CAUTION
!
WARNING
!
DANGER
MANUAL
Very Important Safety
Information
4
Operating Instructions and Parts Manual
Limited Warranty
For one year from the date of purchase, Wayne Water Systems Division ("Wayne") will repair or replace, at its option, for
the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by
Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer.
Be prepared to provide the model number and the serial number when exercising this warranty. All transportation
charges on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect,
improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. THIS IS
THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR
EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations
of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you
specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or
its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of prof-
it or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital,
cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for
such damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you
MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987)
for return authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO._______________ SERIAL NO.__________________________ INSTALLATION DATE_____________
ATTACH YOUR RECEIPT HERE

Summary of content (2 pages)