Instructions
Table Of Contents
- 1 Notes about this Documentation
- 2 Important Notes
- 3 Overview
- 4 Properties
- 4.1 Hardware Description
- 4.1.1 View
- 4.1.2 Labeling and type plate
- 4.1.3 Connectors
- 4.1.4 Display Elements
- 4.1.5 Operating Elements
- 4.1.6 Memory Card Slot
- 4.2 Schematic Diagram
- 4.3 Technical Data
- 4.3.1 Mechanical Data
- 4.3.2 System Data
- 4.3.3 Power Supply
- 4.3.4 Clock
- 4.3.5 Programming
- 4.3.6 ETHERNET
- 4.3.7 Communication Interface
- 4.3.8 Connection Type
- 4.3.9 Digital inputs
- 4.3.10 Digital outputs
- 4.3.11 Analog inputs
- 4.3.12 Analog outputs
- 4.3.13 Climatic Environmental Conditions
- 4.3.14 Analog Temperature Sensors
- 4.3.15 Fieldbus
- 4.3.16 Other
- 4.4 Approvals
- 4.1 Hardware Description
- 5 Function Description
- 6 Mounting
- 7 Connecting
- 8 Commissioning
- 9 e!RUNTIME Runtime Environment
- 10 Diagnostics
- 11 Service
- 12 Removal
- 13 Disposal
- 14 Accessories
- 15 Appendix
- 15.1 Configuration Dialogs
- 15.1.1 Web-Based-Management (WBM)
- 15.1.1.1 “Information” Tab
- 15.1.1.2 “Configuration” Tab
- 15.1.1.2.1 “PLC Runtime Configuration” Page
- 15.1.1.2.2 “TCP/IP Configuration” Page
- 15.1.1.2.3 “Ethernet Configuration” Page
- 15.1.1.2.4 “Configuration of Host and Domain Name” Page
- 15.1.1.2.5 “Routing” Page
- 15.1.1.2.6 “Clock Settings” Page
- 15.1.1.2.7 “Create Bootable Image” Page
- 15.1.1.2.8 “Firmware Backup” Page
- 15.1.1.2.9 “Firmware Restore” Page
- 15.1.1.2.10 “Active System” Page
- 15.1.1.2.11 “Mass Storage” Page
- 15.1.1.2.12 “Software Uploads” Page
- 15.1.1.2.13 “Configuration of Network Services” Page
- 15.1.1.2.14 “Configuration of NTP Client” Page
- 15.1.1.2.15 “PLC Runtime Services” Page
- 15.1.1.2.16 “SSH Server Settings” Page
- 15.1.1.2.17 “DHCP Server Configuration” Page
- 15.1.1.2.18 “Configuration of DNS Server” Page
- 15.1.1.2.19 “Status overview” Page
- 15.1.1.2.20 “Configuration of Connection
” Page - 15.1.1.2.21 “Configuration of General SNMP Parameters” Page
- 15.1.1.2.22 “Configuration of SNMP v1/v2c Parameters” Page
- 15.1.1.2.23 “Configuration of SNMP v3 Users” Page
- 15.1.1.2.24 “WBM User Configuration” Page
- 15.1.1.3 “Fieldbus” Tab
- 15.1.1.4 “Security” Tab
- 15.1.1.4.1 “OpenVPN / IPsec Configuration” Page
- 15.1.1.4.2 “General Firewall Configuration” Page
- 15.1.1.4.3 “Interface Configuration” Page
- 15.1.1.4.4 “Configuration of MAC Address Filter” Page
- 15.1.1.4.5 “Configuration of User Filter” Page
- 15.1.1.4.6 “Certificates” Page
- 15.1.1.4.7 “Security Settings” Page
- 15.1.1.4.8 “Advanced Intrusion Detection Environment (AIDE)” Page
- 15.1.1.5 “Diagnostic” Tab
- 15.1.1 Web-Based-Management (WBM)
- 15.1 Configuration Dialogs
- List of Figures
- List of Tables
172 Appendix WAGO I/O System Compact
751-9301 Compact Controller 100
Manual
Version 1.1.0, valid from FW Version 03.08.07(20)
15.1.1.2.22 “Configuration of SNMP v1/v2c Parameters” Page
The general settings for SNMP v1/v2c are shown on the “Configuration of SNMP
v1/v2c Parameters” page.
“SNMP v1/v2c Manager Configuration” Group
Table 105: WBM “Configuration of SNMP v1/v2c Parameters” Page – “SNMP v1/v2c Manager
Configuration” Group
Parameters
Explanation
Protocol enabled
It is displayed the SNMP protocol for v1/v2c is
enabled. The local community name is deleted when
the protocol is disabled.
Local Community Name
Specify the community name for the SNMP
manager configuration. The community name can
establish relationships between SNMP managers
and agents who are respectively referred to as
“Community” and who control identification and
access between SNMP participants.
The community name can be up to 32 characters
long and must not include spaces.
To use the SNMP protocol, a valid community name
must always be specified. The default community
name is “public.”
Click the [Submit] button to apply the changes. The changes only take effect
after the controller restarts. For this purpose, use the WBM reboot function. Do
not shut down the controller too early!