Instructions
Table Of Contents
- 1 Notes about this Documentation
- 2 Important Notes
- 3 Overview
- 4 Properties
- 4.1 Hardware Description
- 4.1.1 View
- 4.1.2 Labeling and type plate
- 4.1.3 Connectors
- 4.1.4 Display Elements
- 4.1.5 Operating Elements
- 4.1.6 Memory Card Slot
- 4.2 Schematic Diagram
- 4.3 Technical Data
- 4.3.1 Mechanical Data
- 4.3.2 System Data
- 4.3.3 Power Supply
- 4.3.4 Clock
- 4.3.5 Programming
- 4.3.6 ETHERNET
- 4.3.7 Communication Interface
- 4.3.8 Connection Type
- 4.3.9 Digital inputs
- 4.3.10 Digital outputs
- 4.3.11 Analog inputs
- 4.3.12 Analog outputs
- 4.3.13 Climatic Environmental Conditions
- 4.3.14 Analog Temperature Sensors
- 4.3.15 Fieldbus
- 4.3.16 Other
- 4.4 Approvals
- 4.1 Hardware Description
- 5 Function Description
- 6 Mounting
- 7 Connecting
- 8 Commissioning
- 9 e!RUNTIME Runtime Environment
- 10 Diagnostics
- 11 Service
- 12 Removal
- 13 Disposal
- 14 Accessories
- 15 Appendix
- 15.1 Configuration Dialogs
- 15.1.1 Web-Based-Management (WBM)
- 15.1.1.1 “Information” Tab
- 15.1.1.2 “Configuration” Tab
- 15.1.1.2.1 “PLC Runtime Configuration” Page
- 15.1.1.2.2 “TCP/IP Configuration” Page
- 15.1.1.2.3 “Ethernet Configuration” Page
- 15.1.1.2.4 “Configuration of Host and Domain Name” Page
- 15.1.1.2.5 “Routing” Page
- 15.1.1.2.6 “Clock Settings” Page
- 15.1.1.2.7 “Create Bootable Image” Page
- 15.1.1.2.8 “Firmware Backup” Page
- 15.1.1.2.9 “Firmware Restore” Page
- 15.1.1.2.10 “Active System” Page
- 15.1.1.2.11 “Mass Storage” Page
- 15.1.1.2.12 “Software Uploads” Page
- 15.1.1.2.13 “Configuration of Network Services” Page
- 15.1.1.2.14 “Configuration of NTP Client” Page
- 15.1.1.2.15 “PLC Runtime Services” Page
- 15.1.1.2.16 “SSH Server Settings” Page
- 15.1.1.2.17 “DHCP Server Configuration” Page
- 15.1.1.2.18 “Configuration of DNS Server” Page
- 15.1.1.2.19 “Status overview” Page
- 15.1.1.2.20 “Configuration of Connection
” Page - 15.1.1.2.21 “Configuration of General SNMP Parameters” Page
- 15.1.1.2.22 “Configuration of SNMP v1/v2c Parameters” Page
- 15.1.1.2.23 “Configuration of SNMP v3 Users” Page
- 15.1.1.2.24 “WBM User Configuration” Page
- 15.1.1.3 “Fieldbus” Tab
- 15.1.1.4 “Security” Tab
- 15.1.1.4.1 “OpenVPN / IPsec Configuration” Page
- 15.1.1.4.2 “General Firewall Configuration” Page
- 15.1.1.4.3 “Interface Configuration” Page
- 15.1.1.4.4 “Configuration of MAC Address Filter” Page
- 15.1.1.4.5 “Configuration of User Filter” Page
- 15.1.1.4.6 “Certificates” Page
- 15.1.1.4.7 “Security Settings” Page
- 15.1.1.4.8 “Advanced Intrusion Detection Environment (AIDE)” Page
- 15.1.1.5 “Diagnostic” Tab
- 15.1.1 Web-Based-Management (WBM)
- 15.1 Configuration Dialogs
- List of Figures
- List of Tables
WAGO I/O System Compact Appendix 165
751-9301 Compact Controller 100
Manual
Version 1.1.0, valid from FW Version 03.08.07(20)
15.1.1.2.18 “Configuration of DNS Server” Page
The “Configuration of DNS Server” page displays the DNS service settings.
“DNS Server” Group
Table 99: WBM “Configuration of DNS Server” Page – “DNS Server” Group
Parameter
Explanation
Service active
You can enable/disable the DNS server service.
Mode
Select the operating mode of the DNS server.
Proxy
Requests are buffered to optimize
throughput.
Relay
All requests are routed directly.
Static Hosts
This displays the names for IP addresses. If no
assignment was defined, “No static hosts
configured” is displayed.
Add Static Host
You can add static IP addresses and host names
below.
IP Address
Enter a new static assignment,
e.g., “192.168.1.20:hostname”.
You can enter 10 assignments.
Hostname
Enter a host name.
Click the [Submit] button to apply the changes. The changes take effect
immediately.
To accept a new assignment click the [Add] button. The change takes effect
immediately.
Click [Delete] to delete an existing assignment. The change takes effect
immediately.