Instructions
Table Of Contents
- 1 Notes about this Documentation
- 2 Important Notes
- 3 Overview
- 4 Properties
- 4.1 Hardware Description
- 4.1.1 View
- 4.1.2 Labeling and type plate
- 4.1.3 Connectors
- 4.1.4 Display Elements
- 4.1.5 Operating Elements
- 4.1.6 Memory Card Slot
- 4.2 Schematic Diagram
- 4.3 Technical Data
- 4.3.1 Mechanical Data
- 4.3.2 System Data
- 4.3.3 Power Supply
- 4.3.4 Clock
- 4.3.5 Programming
- 4.3.6 ETHERNET
- 4.3.7 Communication Interface
- 4.3.8 Connection Type
- 4.3.9 Digital inputs
- 4.3.10 Digital outputs
- 4.3.11 Analog inputs
- 4.3.12 Analog outputs
- 4.3.13 Climatic Environmental Conditions
- 4.3.14 Analog Temperature Sensors
- 4.3.15 Fieldbus
- 4.3.16 Other
- 4.4 Approvals
- 4.1 Hardware Description
- 5 Function Description
- 6 Mounting
- 7 Connecting
- 8 Commissioning
- 9 e!RUNTIME Runtime Environment
- 10 Diagnostics
- 11 Service
- 12 Removal
- 13 Disposal
- 14 Accessories
- 15 Appendix
- 15.1 Configuration Dialogs
- 15.1.1 Web-Based-Management (WBM)
- 15.1.1.1 “Information” Tab
- 15.1.1.2 “Configuration” Tab
- 15.1.1.2.1 “PLC Runtime Configuration” Page
- 15.1.1.2.2 “TCP/IP Configuration” Page
- 15.1.1.2.3 “Ethernet Configuration” Page
- 15.1.1.2.4 “Configuration of Host and Domain Name” Page
- 15.1.1.2.5 “Routing” Page
- 15.1.1.2.6 “Clock Settings” Page
- 15.1.1.2.7 “Create Bootable Image” Page
- 15.1.1.2.8 “Firmware Backup” Page
- 15.1.1.2.9 “Firmware Restore” Page
- 15.1.1.2.10 “Active System” Page
- 15.1.1.2.11 “Mass Storage” Page
- 15.1.1.2.12 “Software Uploads” Page
- 15.1.1.2.13 “Configuration of Network Services” Page
- 15.1.1.2.14 “Configuration of NTP Client” Page
- 15.1.1.2.15 “PLC Runtime Services” Page
- 15.1.1.2.16 “SSH Server Settings” Page
- 15.1.1.2.17 “DHCP Server Configuration” Page
- 15.1.1.2.18 “Configuration of DNS Server” Page
- 15.1.1.2.19 “Status overview” Page
- 15.1.1.2.20 “Configuration of Connection
” Page - 15.1.1.2.21 “Configuration of General SNMP Parameters” Page
- 15.1.1.2.22 “Configuration of SNMP v1/v2c Parameters” Page
- 15.1.1.2.23 “Configuration of SNMP v3 Users” Page
- 15.1.1.2.24 “WBM User Configuration” Page
- 15.1.1.3 “Fieldbus” Tab
- 15.1.1.4 “Security” Tab
- 15.1.1.4.1 “OpenVPN / IPsec Configuration” Page
- 15.1.1.4.2 “General Firewall Configuration” Page
- 15.1.1.4.3 “Interface Configuration” Page
- 15.1.1.4.4 “Configuration of MAC Address Filter” Page
- 15.1.1.4.5 “Configuration of User Filter” Page
- 15.1.1.4.6 “Certificates” Page
- 15.1.1.4.7 “Security Settings” Page
- 15.1.1.4.8 “Advanced Intrusion Detection Environment (AIDE)” Page
- 15.1.1.5 “Diagnostic” Tab
- 15.1.1 Web-Based-Management (WBM)
- 15.1 Configuration Dialogs
- List of Figures
- List of Tables
WAGO I/O System Compact Appendix 139
751-9301 Compact Controller 100
Manual
Version 1.1.0, valid from FW Version 03.08.07(20)
“Switch Configuration” Group
This group only appears if parameter configuration is supported.
Table 69: WBM “Ethernet Configuration” Page – “Switch Configuration” Group
Parameters
Explanation
Port Mirror
Enable or disable mirroring of the data traffic
between the ports.
None
Both ETHERNET ports are operating
normally.
X1
The entire data traffic between X1 and
the PFC system is mirrored at port X2.
X2
The entire data traffic between X2 and
the PFC system is mirrored at port X1.
Fast Aging
Set here the aging time of unused entries in the list
of MAC addresses with a port assignment to
external network stations.
This field is only enabled in “switched” mode. Fast
aging is only effective in this mode.
Disabled
An unused address entry becomes
obsolete after 200 seconds.
Enabled
An unused address entry becomes
obsolete after 800 microseconds.
Broadcast Protection
You can set the broadcast limit for protection against
overloads.
Disabled
No broadcast packet limit
1 % … 5 %
Limits incoming broadcast packets to
the selected percentage of the total
possible data throughput (10/100 Mbit)
Rate Limit
You can set the basic limitation of the incoming data
traffic.
Disabled
No limitation of the incoming data traffic
64 kbps …
99 mbps
Limits the incoming data traffic to the
entered value
Click [Submit] to apply the change. The change takes effect immediately.