INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOOD STEAMERS MODEL VSX24G VSX36G VSX42GT VSX24E VSX36E VSX42ET VSX24D VSX36D VSX42DT VSX36R VSX42RT ML-52163 ML-52360 ML-52832 ML-52164 ML-52829 ML-52833 ML-52827 ML-52830 ML-52834 ML-52831 ML-52835 MODEL VSX24 VULCAN-HART COMPANY, FORM 30798 (Rev. A, 10-95) P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL.
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.
INSTALLATION, OPERATION, SERVICE & PARTS MANUAL CONVECTION FOOD STEAMERS GAS, ELECTRIC, REGENERATIVE OR DIRECT STEAM MODELS VSX24, VSX36 & VSX42 INDEX PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Your Vulcan Steam Cooker is produced with quality workmanship and material. Proper installation, usage and maintenance of your steam cooker will result in many years of satisfactory performance.
DESCRIPTION PAGE OPERATION (CONT’D.
INSTALLATION UNPACKING This steam cooker was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage. If the cooker is found to be damaged after unpacking, save the packaging material and contact the carrier within 15 days of delivery.
In the United States: STEAM CONNECTIONS 1. State and local codes. Provide dry steam to the inlets. If the steam is heavy with condensate, install a ball float trap before the pressure regulator valve. To ensure rapid heat-up of heavy cold loads, the steam supply line must be sized to maintain pressure and flow as follows: 2. National Fuel Gas Code, ANSI-Z233.1 (latest edition). Copies may be obtained from The American Gas Assoc., Inc., 1515 Wilson Blvd., Arlington, VA 22209.
Testing The Gas Supply System DRAIN CONNECTIONS (Fig’s. 2-12) When test pressures exceed 1⁄2 psig (3.45 kPa), the generator and its individual shutoff valve must be disconnected from the gas supply piping system. Drain connections must be the open air gap type. Provide a suitable drain under the drain pipes. For proper drainage, a floor sink with minimum of 12" depth is recommended. When test pressures are 1⁄2 psig (3.
SERVICE CONNECTIONS DIRECT STEAM, VSX24D FIG. 2 LEGEND A. B. C. D. COLD SUPPLY WATER CONNECTION: 1⁄4” TUBING FOR COLD WATER CONDENSER SUPPLY, AND BOILER FEED. STEAM SUPPLY CONNECTION: 3⁄4” NPT FOR STEAM COOKING (A STEAM PRESSURE REDUCING VALVE IS MOUNTED AS STANDARD AND SET FOR 10 PSI MAXIMUM INPUT TO UNIT). ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF THIS CONNECTION.
SERVICE CONNECTIONS DIRECT STEAM, VSX36D FIG. 3 LEGEND A. B. C. D. COLD SUPPLY WATER CONNECTION: 1⁄4” TUBING FOR COLD WATER CONDENSER, AND BOILER FEED. STEAM SUPPLY CONNECTION: 3⁄4” NPT FOR STEAM COOKING. (A STEAM PRESSURE REDUCING VALVE IS MOUNTED AS STANDARD AND SET FOR 10 PSI MAXIMUM INPUT TO UNIT.) ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF THIS CONNECTION.
SERVICE CONNECTIONS DIRECT STEAM, VSX42DT FIG. 4 LEGEND A. B. C. D. COLD SUPPLY WATER CONNECTION: 1⁄4” TUBING FOR COLD WATER CONDENSER, AND BOILER FEED. STEAM SUPPLY CONNECTION: 3⁄4” NPT FOR STEAM COOKING. (A STEAM PRESSURE REDUCING VALVE IS MOUNTED AS STANDARD AND SET FOR 10 PSI MAXIMUM INPUT TO UNIT.) ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF THIS CONNECTION.
SERVICE CONNECTIONS REGENERATING STEAM, VSX36R FIG. 5 LEGEND A. B. C. D. STEAM SUPPLY CONNECTION: 3⁄4” NPT FOR STEAM INLET TO BOILER. (A STEAM PRESSURE REDUCING VALVE IS SHIPPED WITH THE UNIT AND MUST BE FIELD INSTALLED AND ADJUSTED FOR 15 PSI MAXIMUM TO THE UNIT.) ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF THIS CONNECTION.
SERVICE CONNECTIONS REGENERATING STEAM, VSX42RT FIG. 6 LEGEND A. B. C. D. STEAM SUPPLY CONNECTION: 3⁄4” NPT FOR STEAM INLET TO BOILER. (A STEAM PRESSURE REDUCING VALVE IS SHIPPED WITH THE UNIT AND MUST BE FIELD INSTALLED AND ADJUSTED FOR 15 PSI MAXIMUM TO THE UNIT.) ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF THIS CONNECTION.
SERVICE CONNECTIONS GAS HEAT, VSX24G FIG. 7 LEGEND A. B. C. D. GAS CONNECTION: 3⁄4” NPT. ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF THIS CONNECTION.) DRAIN: COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY 31⁄2” IN DIAMETER. (PROVIDE AN OPEN AIR GAP TYPE DRAIN DIRECTLY UNDER UNIT FRAME. DO NOT CONNECT SOLIDLY TO ANY DRAIN CONNECTION.
SERVICE CONNECTIONS GAS HEAT, VSX36G FIG. 8 LEGEND A. B. C. D. GAS CONNECTION: 3⁄4” NPT. ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF THIS CONNECTION.) DRAIN: COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY 31⁄2” IN DIAMETER. (PROVIDE AN OPEN AIR GAP TYPE DRAIN DIRECTLY UNDER UNIT FRAME. DO NOT CONNECT SOLIDLY TO ANY DRAIN CONNECTION.
SERVICE CONNECTIONS GAS HEAT, VSX42GT FIG. 9 LEGEND A. B. C. D. GAS CONNECTION: 3⁄4” NPT. ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF THIS CONNECTION.) DRAIN: COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY 31⁄2” IN DIAMETER. (PROVIDE AN OPEN AIR GAP TYPE DRAIN DIRECTLY UNDER UNIT FRAME. DO NOT CONNECT SOLIDLY TO ANY DRAIN CONNECTION.
SERVICE CONNECTIONS ELECTRIC HEAT, VSX24E FIG. 10 LEGEND A. B. C. D. JUNCTION BOX: J.I.C. 6X6X4 FOR ELECTRICAL SUPPLY CONNECTION FOR HEAT. ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (NOT PROVIDED IF A STEP DOWN TRANSFORMER IS FURNISHED.) COLD SUPPLY WATER CONNECTION: 1⁄4” NPT FOR BOILER DRAIN AND COMPARTMENT DRAIN COLD WATER CONDENSERS. DRAIN: COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY 31⁄2” IN DIAMETER.
SERVICE CONNECTIONS ELECTRIC HEAT, VSX36E FIG. 11 LEGEND A. B. C. D. JUNCTION BOX: J.I.C. 6X6X4 FOR ELECTRICAL SUPPLY CONNECTION FOR HEAT. ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (NOT PROVIDED IF A STEP DOWN TRANSFORMER IS FURNISHED.) COLD SUPPLY WATER CONNECTION: 1⁄4” NPT FOR BOILER DRAIN AND COMPARTMENT DRAIN COLD WATER CONDENSERS. DRAIN: COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY 31⁄2” IN DIAMETER.
SERVICE CONNECTIONS ELECTRIC HEAT, VSX42ET FIG. 12 LEGEND A. B. C. D. JUNCTION BOX: J.I.C. 6X6X4 FOR ELECTRICAL SUPPLY CONNECTION FOR HEAT. ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (NOT PROVIDED IF A STEP DOWN TRANSFORMER IS FURNISHED.) COLD SUPPLY WATER CONNECTION: 1⁄4” NPT FOR BOILER DRAIN AND COMPARTMENT DRAIN COLD WATER CONDENSERS. DRAIN: COMPARTMENT, BOILER AND EXHAUST GROUP APPROXIMATELY 31⁄2” IN DIAMETER.
START-UP TEST RUN After the appliance is installed and proper service connections have been made, thoroughly test the steam cooker before operation. Gas Powered Steam Generator 1. Open manual gas shutoff valve, and if the appliance has a manual blowdown valve, close it. Open left cabinet door and turn water fill and power switch ON. The red light will come on and water will fill boiler to the required level in about 15 minutes. Observe water level gauge glass to verify.
7. Turn power switch OFF. Amber light will go out. 8. Blow down boiler (see BLOW DOWN BOILER in this manual). Direct Steam Powered Cooker 1. Set both timer knobs to “0”. Open both compartment doors and observe that no steam has entered cooking compartments. Close doors. 2. Set both timer knobs to 2 minutes. READY lights will go off, COOKING lights will come on, and steam will be heard entering the compartments.
OPERATION WARNING: THE STEAMER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE STEAMER. THE COOKING COMPARTMENTS CONTAIN LIVE STEAM. STAY CLEAR WHILE OPENING EACH DOOR. CONTROLS — CABINET BASE GENERATOR (Fig. 13) Handhole Cover Assembly — when unbolted and removed, allows internal examination and cleaning of boiler if required. Water Level Gauge Assembly — permits visual confirmation that water level is being maintained in the boiler during operation.
Boiler Blowdown Valve — plumbed to the drain pipe of the boiler, and when specified as automatic, will be a solenoid (electrically operated) valve which will close to assist in maintaining proper water level in the boiler and open whenever the steamer is turned off to blow down sediment and scalant that may be lodged in the chamber of the boiler. Pressure Gauge — indicates boiler steam pressure.
CONTROLS — COMPARTMENT (Fig. 14) The upper section of the steamer consists of two cooking compartments. Each compartment functions independently with its own controls, and is a separated, sealed steam chamber during the cooking operation. Gasket Plate Screw (Not Shown) — a stainless steel screw on the gasket plate immediately adjacent to each corner of the gasket allows adjustment of the gasket if necessary.
Shutdown CLEANING 1. Turn the boiler power switch to the OFF position to extinguish the pilot light. 2. To make the pilot light and main burners inoperable, turn the gas combination control valve clockwise until it stops (OFF position). 3. To completely shut off pilot light and main burners, close the main gas valve. Never use steel wool on stainless steel surfaces. Never apply food oils or petroleum lubricants directly to the door gasket.
Remove the “Y” strainer upstream of the drain solenoid valve by unscrewing the cap on the section protruding down towards the floor. Remove the screen and any foreign particles. Rinse the screen thoroughly and replace. Replace cap. The pressure regulating valve strainer will become clogged if dirty steam lines are connected to direct steam models. Remove the hex nut on the bottom of the pressure regulating valve to clean the strainer and valve seat. MAINTENANCE WARNING: THE STEAMER AND ITS PARTS ARE HOT.
COOKING CHART The following table lists suggested cooking times and weights. These times, which will vary depending on initial product temperature, size, shape, etc., are approximate and should be adjusted to suit your operation. PRODUCTS TO BE COOKED IN SOLID PANS PRODUCT Eggs, Scrambled TIMER SETTING IN MINUTES 10-12 Rice, Long Grain (Cover with 4 cups water/lb.
PRODUCTS TO BE COOKED IN PERFORATED PANS (Cont’d.) PRODUCT TIMER SETTING IN MINUTES WEIGHT PER PAN Salmon Fillets, Frozen, 8 Oz. Ea. 5 71⁄2 Lb. Scallops, Fresh 4 3 Lb. Scrod Fillets, Fresh 3-5 4 Lb. Eggs Hard Cooked Soft Cooked Soft Yoke for Caesar Salad 15 9-10 6-8 4 Dozen 4 Dozen 4 Dozen Chicken, Breasts, Legs, Thighs 20 15 Lb. Turkey, Frozen Breasts (2) Cut Lengthwise 90 55 6-7 Lb. Ea. 20-25 Lb. Corned Beef Hot Dogs or Wieners Asparagus Spears Frozen Fresh 40-75 3 10-12 5 6-8 Lb.
PRODUCTS TO BE COOKED IN PERFORATED PANS (Cont’d.) PRODUCT Corn Yellow Whole Kernel, Frozen Cobbettes, Frozen Corn-On-Cob, Fresh TIMER SETTING IN MINUTES 5 8 16-18 10-12 16-18 WEIGHT PER PAN 5 Lb. 27 Ears 80 Ears 18 Ears 54 Ears Peas, Green 6 5 Lb. Potatoes, Whole Russet 55 10 Lb. Spinach Chopped, Frozen Defrosted Fresh Cut 17 5 3 6 Lb. 6 Lb. 2 Lb. Squash, Acorn, Halves 25 10 Halves Zucchini, Slices Frozen Mixed Vegetables 8 10 Lb. 6-7 5 Lb.
TROUBLESHOOTING PROBLEM Steamer Will Not Heat or Build Pressure Pilot Won’t Light Generator Leaks Water 30 CAUSE CORRECTIVE MEASURES 1. Problem with low water cut-off. Replace low water cut-off control. 2. Problem with pressure switch. Replace pressure switch. 3. Loose wiring. Check against diagram and tighten connections. 4. Problem with combination control valve on gas base generator. Replace valve. 5. Problem with pressure reducing valve on steam generator.
PROBLEM CAUSE CORRECTIVE MEASURES 1. Loose or misadjusted door switch striker. Adjust and tighten bracket on door. 2. Boiler not building pressure. Adjust pressure switch. 3. Problem with steam solenoid valve. Replace steam solenoid valve. 1. No electric power to controls. Check connections. 2. No fuel supply to steamer (steam to steam heated generator, gas to gas heated generators, power to heating elements). Examine physical plant for flow problems. 3. Problem with pressure switch.
PROBLEM Steam Leak Around Door Heat Coming On Without Water (Dry Firing) Pressure Gauge Not Working Steam Leaking Inside Unit 32 CAUSE CORRECTIVE MEASURES 1. Worn gasket. Replace gasket. 2. Drain line obstructed or not to an open gap drain. Clean or open drain line. 3. Cold water condenser not spraying properly. Check solenoid valve and spray nozzle for proper operation. Replace as required. 4. Door liner needs adjustment. Lift off door liner and adjust pressure springs to obtain uniform seal.
SERVICE These service procedures should only be performed by a qualified servicer. 7. Check that all connections and terminals are securely fastened (no open circuits). WARNING: THE STEAMER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE STEAMER. THE COOKING COMPARTMENTS CONTAIN LIVE STEAM. STAY CLEAR WHILE OPENING EACH DOOR. 8. Check that all connections are made according to compartment control wiring diagram.
Local water conditions may cause excessive boiler scale build-up and cause the generator and compartment controls not to work. Proper periodic service must be performed as outlined in the operating and service instructions. It may also be necessary to install a water conditioner on the generator water feed. Contact your local water conditioner dealer. Inspect and Clean Inside of Generator Shell Flush (blow down) steam generator. Drain water from the shell with the electric power OFF (no heat on).
With the probe wire removed, check the probes and contactors in the following manner: 1. With an ohmmeter, check the probe at wire connection and shell. There should be no resistance present when the boiler is empty. If resistance is present, remove and clean the probes. Also check for a cracked insulator, then reinstall probes and check. You should read continuity between the probes and shell only when the boiler shell is full of water. 2. Check low level and differential contactors.
On electric boilers, the high limit thermostat is located behind the contactor box cover. On electric boilers with two heating elements, the thermostat is connected to one of the heating element lugs. On electric boilers with four heating elements, the thermostat is located between the center pair of elements at the top of the elements. Steam Supply Solenoid The magnetic coil of a solenoid valve is removed from the valve by removing the snap catch at the center top.
Boiler Blowdown Solenoid Valve Does Not Drain If your steamer has an automatic blowdown drain valve, when the blowdown button is depressed, the boiler blowdown valve opens. If your steamer has a manual blowdown drain valve, close it. The water contained in the boiler, being under pressure, should be blown through this valve and be noticeably visible exhausting out the steamer drain.
Blow pilot flame out. The reading when the protection valve closes (drop-out point) should be at least 5 MV below first reading. If first reading is correct, but dropout point is not, problem is in the combination control valve. An open circuit check of the thermocouple should give a meter reading of 30 to 40 MV. If removed element shows a pronounced scale buildup on its heating tubes, the other elements should be removed and mechanically cleaned to remove the scale. This will prolong their life.
REPLACEMENT PARTS LIST REPLACEMENT PARTS ORDERING The following information must accompany a replacements parts order or it cannot be filled. A. B. C. D. Model and style or serial number. Type of gas (natural or propane). Voltage and phase. Appliance finish, permafinish, stainless steel, etc. (if applicable to part to be replaced). Use rating plate located inside base cabinet door to help you obtain the information listed above.
COMPARTMENT DOOR 21 2 3 4 1 5 6 20 7 8 9 19 18 10 17 16 11 12 13 14 PL-50859 40 15
COMPARTMENT DOOR ILLUS. PL-50859 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 PART NO. 836976 840489 840487 840484 840481 840500 840477 840479 840493 840491 836975 836974 SC-120-81 836973 836919 840479 840485 RP-2-13 SC-115-42 840480 840483 NAME OF PART AMT. Latch Plate Assy. ....................................................................................................................... 1 Pin - Lock ........................................................................................
CONTROL PANEL 1 READ Y 2 COO KING 13 9 THRU 12 TIME R 8 READ Y 3 COO KING 4 THRU 7 TIME R PL-50794 42
CONTROL PANEL ILLUS. PL-50794 1 2 3 4 5 6 7 8 9 10 11 12 13 PART NO. 840829 843808 843808 843781-3 843781-4 843806 843835 843807 843781-3 843781-4 843806 843835 843807 843811 NAME OF PART AMT. Panel - Control ........................................................................................................................... Light - Indicator (Red) (Cooking) (120 V.) ............................................................................... Light - Indicator (Red) (Cooking) (120 V.) ........
ELECTRICAL COMPONENTS 1 2 9 3 4 5 6 7 8 44 PL-50796
ELECTRICAL COMPONENTS ILLUS. PL-50796 1 2 3 4 5 6 7 8 9 PART NO. 843946 843947 WL-7-6 SD-35-88 WL-7-6 SD-35-88 840832 840833 WS-29-18 NAME OF PART AMT. Panel - Component .................................................................................................................... Relay ........................................................................................................................................... Lockwasher ...............................................................
PLUMBING TO TO S A TE OT ME H R ER SI V CA DE IT Y 2 1 12 3 11 4 5 10 6 9 8 7 PL-50797 46
PLUMBING ILLUS. PL-50797 1 2 3 4 5 6 7 8 9 10 11 12 PART NO. FP-81-34 843948 843949 843834 FP-15-5 843950 843837 FP-47-4 FP-15-5 FP-47-4 843836 843951 NAME OF PART AMT. Tee .............................................................................................................................................. Tubing ......................................................................................................................................... Tubing .......................................
LEVEL CONTROL BOX (36" & 42" GAS GENERATORS) 1 3 4 2 5 6 7 10 9 PL-50611 48 8
LEVEL CONTROL BOX (36" & 42" GAS GENERATORS) ILLUS. PL-50611 1 2 3 4 5 6 7 8 9 10 PART NO. 880397 880675 817256 SC-53-5 817257 817234-1 817234-1 SC-66-2 SC-53-41 SC-41-50 NAME OF PART AMT. Connector 3⁄8" x 90 Deg. Sealtite ............................................................................................. AR Connector 3⁄8" Straight Sealtite ................................................................................................ AR Box - Level Control ..................................
GENERATOR CONTROL BOX (36" & 42" GAS & ELECTRIC) 1 2 3 4 5 8 9 7 10 - 11 25 12 6 24 23 22 21 17 13 14 20 15 18 16 19 50 PL-50612
GENERATOR CONTROL BOX (36" & 42" GAS & ELECTRIC) ILLUS. PL-50612 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PART NO. SC-66-2 817222 881551-1 SC-53-2 833488 817264 NS-11-18 881605 881721 881552 817227 881579 881673 SC-119-53 SC-66-2 SC-53-2 817792 RS-30-9 NS-31-15 880396 SC-53-5 FE-23-87 FP-54-8 880395 907998 NAME OF PART AMT. Mach. Screw 6-32 x 3⁄8 Phil. Truss Hd. .....................................................................................
GENERATOR CONTROL BOX (24" GAS) 1 2 3 36 - 37 4 38 5 6 7 35 15 - 16 34 8 14 33 32 13 9 39 40 12 11 41 31 10 30 29 19 28 27 20 21 - 22 26 17 25 24 23 PL-50613 52 18
GENERATOR CONTROL BOX (24" GAS) ILLUS. PL-50613 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 PART NO.
GENERATOR CONTROL BOX (24" ELECTRIC) 7 4 3 8 6 2 9 5 10 1 25 11 12 13 14 18 24 21 20 19 22 23 PL-50614 15 16 - 17 54
GENERATOR CONTROL BOX (24" ELECTRIC) ILLUS. PL-50614 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PART NO. 817081 WS-3-45 817081-3 SC-53-41 907998 FP-54-8 880395 907998 FE-23-87 SC-53-5 880396 SC-53-3 SC-66-2 881673 881579 817082-1 817082-2 817264 SC-41-50 907998 SC-93-5 881605 881721 880397 880675 NAME OF PART AMT. Box - Boiler Control ................................................................................................................... 1 Washer ......................
GENERATOR CONTACTOR BOX & HEATER (LARGE SHELL) 3 1 - 2 23 4 6 22 5 7 21 8 20 19 9 14 15 16 10 13 11 - 12 18 17 56 PL-50615
GENERATOR CONTACTOR BOX & HEATER (LARGE SHELL) ILLUS. PL-50615 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NO. SC-41-19 WL-7-19 817234-1 SC-66-2 880410 NS-15-11 817234-1 881236 881237 881528 880314 SC-53-41 FE-14-25 881654 881655 881656 SC-53-2 881529 SC-53-2 FE-23-87 SC-53-2 833512 833513 NAME OF PART AMT. Cap Screw 5⁄16-18 x 2 Hex Hd. ................................................................................................. 16 Lockwasher 5⁄16 External Shakeproof ..........
GENERATOR CONTACTOR BOX & HEATER (SMALL SHELL) 7 10 8 2 1 3 5 6 9 4 11 12 24 - 25 13 21 19 20 18 14 17 16 23 15 22 PL-50616 58
GENERATOR CONTACTOR BOX & HEATER (SMALL SHELL) ILLUS. PL-50616 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PART NO. SC-66-2 RS-30-9 817792 817222 SC-41-19 WL-7-19 817234-1 SC-66-2 880410 NS-15-11 817234-1 881236 881237 833512 SC-53-2 911503-4 FP-83-59 817043 880314 SC-53-2 833514 SC-53-2 817044 817242 SC-53-2 NAME OF PART AMT. Mach. Screw 6-32 x 3⁄8 Phil. Truss Hd. ..................................................................................... Rivet - Dome .125 .............
GENERATOR 4 3 8 7 6 5 11 10 9 2 1 26 13 12 25 14 15 24 16 17 23 22 18 21 19 20 STEAM GENERATOR - LARGE & SMALL, REGENERATIVE & ELECTRIC 37 30 29 34 33 32 31 36 35 28 27 53 52 38 54 41 40 39 42 43 51 44 50 49 PL-50617 48 47 46 45 STEAM GENERATOR - LARGE & SMALL, GAS 60
GENERATOR ILLUS. PL-50617 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 PART NO.
REGENERATING STEAM BOILER 5 2 3 6 4 1 20 7 19 8 9 THRU 13 14 - 15 16 17 18 62 PL-50618
REGENERATING STEAM BOILER ILLUS. PL-50618 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 PART NO. 833152 881057 881342 881865 880028 880413 880410 881047 881043 SC-119-34 WS-5-43 881046 NS-15-11 881049 881048 881050-1 881164-1 881054 881044-1 843979-1 NAME OF PART AMT. Gauge - Pressure 0-31 P.S.I. 1⁄4 MPT ...................................................................................... 1 Bracket - Pressure Gauge ..................................................................................
GENERATOR COMBUSTION CHAMBER 18 3-4 2 1 17 9 16 5-6 14 15 13 11 PL-50619 12 64 10 7 8
GENERATOR COMBUSTION CHAMBER ILLUS. PL-50619 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 PART NO. FP-54-27 FP-23-24 817200 817924 817508 817363-1 817916-1 821076 821075 817208 821078 817209 500235 817167 817166 FP-84-44 FP-54-27 NAME OF PART AMT. Nipple 3⁄4 x 1 3⁄8 TBE (SST) ......................................................................................................... 1 Coupling - 3⁄4 N.P.T. Pipe ..................................................................................................
GENERATOR FRAME 1 2 16 THRU 23 3 4-5 9 14 10 11 PL-50620 12 15 13 66 6-7-8
GENERATOR FRAME ILLUS. PL-50620 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PART NO. 881526 881536 881540-1 841985 843909 842469 842199 843908 881541-1 WS-17-6 WL-6-17 SC-41-1 881525 NS-13-40 881536 881849-16 881849-13 881537-11 881537-12 881578 881578-1 843905-1 843905-2 804556 804555 840414-1 817176 817316 843862 NAME OF PART AMT. Leg - W/6" Adjustable Flange Foot .......................................................................................... Panel - Side ..................
PANELS 1 2 PL-50798 3 68
PANELS ILLUS. PL-50798 1 2 3 PART NO. 843831 843830 SC-53-3 NAME OF PART AMT. Top - Housing ............................................................................................................................. 1 Panel - Enclosure (R.H.) ........................................................................................................... 1 Mach. Screw 10-24 x 3⁄4 Truss Hd., Slotted .............................................................................
ELECTRONIC IGNITION (GAS STEAMERS) ILLUS. PL-50991 1 2 3 4 5 6 7 70 PART NO. 821089-1 821089-2 821089-3 817362-1 836914-2 817362-2 836914-1 NAME OF PART AMT. Orifice - Natural Gas Pilot ......................................................................................................... Orifice - Propane Pilot .............................................................................................................. Pilot Body - Electronic Ignition System .......................................
FORM 30798 (Rev.