Specifications

58 D-302756
4.12.2 Define PGM
For the PGM output, you can select disable, turn on, turn off or pulse active (turn on for predefined period,
selected by PULSE TIME), as follows:
ARM AWAY (upon AWAY arming).
ARM HOME (upon HOME arming).
DISARM (upon disarming).
MEMORY (activated upon registration of an alarm in the memory, turned off upon memory clearing).
DELAY (during exit / entry delays).
KEYFOB (upon AUX button pressing in the keyfob transmitter).
ZONES (by disturbance in each
of 3 selected zones, irrespective of arming / disarming). If you select toggle,
the PGM output will be turned on upon event occurrence in these zones and will be turned off upon next
event occurrence, alternately.
LINE FAIL: PGM output is ON if telephone line is disconnected.
For PGM devices, you can select the following actions:
FLASH ON ALARM - you can select no flash or all light flash, to control PGM lighting devices in alarm
conditions.
LOCKOUT TIME - you can enter daytime limits between which PGM lighting devices controlled by sensors will
be off, even when the associated sensors are triggered.
A. To Configure Output Parameters
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
There are two sub-menus "DEFINE PGM" and "PGM GENERAL DEF".
The PowerMaster-10 display will first read "DEFINE PGM".
3.
4.
5.
or
Select between "pulse time 2s", "pulse time 30s", "pulse time
2m" and "pulse time 4m"
6.
7.
8.
or
Select between "disable", "turn ON", "turn OFF" and "pulse
active".
9.
10.
11.
12.
or
Select between "disable", "turn ON", "turn OFF" and "pulse
active".
disable
PGM: BY ARM HOME
PGM: BY ARM AWAY
disable
PGM: BY ARM AWAY
pulse time 2s
PGM: PULSE TIME
DEFINE PGM
DEFINE OUTPUTS