Specifications

D-302756 49
4.9 Arming/Disarming Options And Exit/Entry Delay
4.9.1 Configuring Exit Modes
Here you determine exit delay mode options. Three types of exit delay modes are available:
restart exit - Exit delay restarts when the door is reopened during exit delay. The restart occurs once only.
Restarting the exit delay is helpful if the user re-enters immediately after going out to retrieve an item that he left
behind.
off by door - When the door is closed, the exit delay is automatically terminated (even if the defined exit delay
was not completed).
normal (default) - The exit delay is exactly as defined, regardless of whether the door is open or closed.
To Configure the Exit Modes
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
3.
or
4.
5.
or
Select between "restart exit", "off by door", and "normal".
6.
You can now press the or button to program any other
menu in "
DEFINE PANEL
" or press the button to take you to "
<OK>
TO EXIT
".
4.9.2 Configuring Entry Delays Duration
Two different entry delays allow the user to enter the protected site (while the system is in the armed state) via 2
specific doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires. Slow-rate warning beeps
start sounding once the door is opened, until the last 10 seconds of the delay, during which the beeping rate
increases. Locations No. 1 (entry delay 1) and 2 (entry delay 2) allow you to program the length of these delays.
Available options for each delay are: "00s", "15s" (default for entry delay 2), "30s" (default for entry delay 1),
"45s", "60s", "3m" and "4m".
Note: To comply with CP-01 requirements, "
00s
" and "
15s
" options are not available.
Note: To comply with EN requirements, the entry delay must not exceed 45 sec
.
Note: To comply with UL requirements, the entry delay must not exceed 15 sec
.
To Configure the Duration of the Entry Delays
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
*
01:ENTRY DELAY 1
DEFINE PANEL
09:EXIT MODE
normal
09:EXIT MODE
01:ENTRY DELAY 1
DEFINE PANEL