User's Manual
Table Of Contents
- 1. Introduction
- 2. Operating the PowerMaster 360 System
- Basic Arming and Disarming
- Preparing to Arm
- Arming ‘AWAY' / ‘HOME'
- Disarming and Stopping Alarm
- Disarming under Duress
- Partition Selection Process
- Switching from ‘HOME’ to ‘AWAY’
- Switching from ‘AWAY’ to ‘HOME’
- Arming AWAY or HOME ‘Instant’
- Forced Arming AWAY or HOME
- Arming in the Latchkey Mode
- Initiating Panic Alarm
- Initiating Fire Alarm0F or Emergency Alarm
- Chime ON/OFF
- 3. Reviewing Troubles and Alarm memory
- 4. Menus and Functions
- A.1 Entering the User Settings Menu & Selecting a Setting Option
- A.2 Returning to the Previous Step or Exiting the USER SETTINGS Menu
- A.3 Buttons used for Navigation & Setting
- B.1 Setting the Zone Bypass Scheme
- B.2 Reviewing the Zone Bypass Scheme
- B.3 Recalling the Zone Bypass Scheme
- B.4 Programming User Codes
- B.5 Programming the Duress Code
- B.6 Add / Delete Proximity Tags
- B.7 Add / Delete Keyfob Transmitters
- B.8 Setting the Time & Time Format
- B.9 Setting the Date & Date Format
- B.10 Enabling / Disabling Auto-Arming
- B.11 Setting the Auto-Arming Time
- B.12 Programming Email, MMS and SMS Reporting
- B.13 Enabling / Disabling the Squawk Option
- B.14 Serial Number
- B.15 PowerLink Parameters4F
- 5. Event Reporting and Control by SMS
- 6. Special Applications and Functions
- 7. Testing the System
- 8. Maintenance
- APPENDIX A. FUNCTIONS OF CONTROLLING DEVICES
- APPENDIX B. PARTITIONING
- APPENDIX C. GLOSSARY
- APPENDIX D. HOME FIRE ESCAPE PLANNING
- APPENDIX E. SPECIFICATIONS
- E1. Functional
- E2. Wireless
- E3. Electrical
- E4. Communication
- E5. Physical Properties
- E6. Peripherals and Accessory Devices
- APPENDIX F. COMPLIANCE WITH STANDARDS
MENUS AND FUNCTIONS
D-305736 PowerMaster 360 User's Guide 25
6
You can now enroll another proximity tag. You can also select another option in the User Settings menu (see
section A.1), or quit programming (see section A.2).
7
If no proximity tag is enrolled in the system, the display reads [
NO EXISTING DEV.
].
8
To abort the procedure, press the button.
9
This setting can be performed only after completing steps 1 - 5 of section B.5A.
10
The
symbol now appears next to the newly selected Partitions.
11
You can now repeat steps 2 - 7 to program or edit another Proximity tag.
12
You can now add or delete another proximity tag. You can also select another option in the User Settings
menu (see section A.1 and section A.2), or quit programming (see section A.3).
B.7 Add / Delete Keyfob Transmitters
A portable keyfob transmitter may be assigned to each of the user codes 1-8 for better, quicker and safer
arming/disarming and other control functions. Each keyfob should be assigned with a serial No. 1-8 and
enrolled into the system correspondingly.
Partition Option (For information about Partition option - see Appendix B)
If the Partition option is enabled in the control panel, each of the 8 keyfobs can be authorized by the Master
User to arm and disarm any combination, or all 3 partitions, irrespective of the authorization of its corresponding
user code.
♦ Here you can add (enroll) the 8 Keyfob transmitters and define which of the 3 partitions each of the keyfob
will be authorized to arm and disarm, or delete keyfobs as required.
1. Before anything else, gather up all keyfob units you intend to enroll and make sure they all have
batteries installed and that they are active (the LED blinks upon pressing any of the buttons).
2. Carefully read the section titled "Additional Information" according to the indicated references
1
etc –
see table at end of this section.
A. To Add (Enroll) a Keyfob
1.
KEYFOBS
Enter the [USER SETTINGS] menu, select the [KEYFOBS] option and press
.
1
2.
ADD NEW KEYFOB
The display will read [ADD NEW KEYFOB].
4
To enroll a new keyfob press
.
3.
ENROLL NOW or
The display offers you two alternative methods to enroll a keyfob:
ENTR ID:xxx-xxxx
A: ENROLL NOW: Press and hold the AUX button on the selected keyfob
until the LED is constantly on.
2
This procedure completes the enrollment.
4a.
DEVICE ENROLLED
If enrollment was successfully completed, a "Happy Tune"
☺
sounds and
the display reads [DEVICE ENROLLED] for a short duration and then
changes to read the keyfob's details. Continue to step 5.
☺
Go to step 5
4b.
ID No. 300-5786
B: ENROLLMENT BY DEVICE ID: Enter the 7-digit number that appears on
the keyfob sticker and then press to confirm. To complete the
enrollment procedure, see Note 9 in the Additional Information table below.
ID ACCEPTED
If a valid ID was entered, a "Happy Tune" ☺ sounds and the display reads
[ID ACCEPTED] for a short duration and then changes to read the keyfob's
details. Continue to step 5.
☺
Go to step 5
5.
F01:keyfob
The display shows the allocated keyfob serial No (user No.), which is always
the first free number, and the keyfob's ID number; for example:
[F01:Keyfob] alternating with [ID No. 300-5786].
ID No. 300-5786