Energy Guide

Troubleshooting
ELECTRICAL SHOCK HAZARD
Disconnect Electrical Power Before
Beginning Removal of Parts
BeforeMaintenance
1. Checkouttheuseriftheuserusesa115VAC,60Hz.only15ampereelectricalsupply,andhave
properlygrounded,ensurethemaintaineragainstelectricalshock.
2. Checkouttheleadsloose?Turnoff?Shortcircuit?Ifhavesuchproblems,forecloseinturn.
BasicChecking
The icemaker has some trouble, through the appearance phenomena judges. So the service
technicianmustcheckitthoroughly,thenmaintain.
Hearing
¾ Hearingtheuser'sdepictionabouttheicemakeratusingprocessandthephenomena.Tryto
understandwhatisthe defectandhow didtheuser operatethe icemakerbefore callingfor
service.
¾ Iftherunningsoundisnormal?
Looking
¾ Checkthepipeofcoolingsystem,especiallytheweldingpoint.Ifthereissomeoil,thegasis
leakoutsothatnoicemakingorlessiceproduced.
¾ Ifthecycleoftheicemakingandharvestisnormal?
¾ Checkthewatersystem,especiallytheconnection.Ifthereissomewaterleakage.
¾ Checkifthewaterfilterneedstobereplaced.
¾ Checkiftheicemakerinstalledaccordingtotheusermanual.
¾ Checkiftheicemakerneedstobecleaned.
Touching
¾ Touch thehotgaspipe(withtheevaporationweld),feelingthetemperature.Attheicemaking
stage,feelingcool.Attheiceharveststage,feelinghot.
¾ Touchthecapillarytube(thedriernearby),feelingtepefaction.
TroubleshootingGuide
Thistroubleshootingguideintheusermanualshouldbereadbeforethisguide.Besureonlywhen
thetroubleshootinginusermanualcan’thelpyousolvetheproblem,turntothisguide.
TroubleshootingGuide
.Themachinedoesnotmakeice