Installation GUIDE 5 SERIES Built-in Gas Rangetops VRT530 VRT536 VRT548
Table of Contents Warnings & Important Safety Information ________________________________________________________________ 3 Dimensions ________________________________________________________________________________________ 4 Specifications _______________________________________________________________________________________ 5 Clearance Dimensions ________________________________________________________________________________ 6 Electrical & Gas Requirements ______________________________________________
Important - Please Read and Follow • Before beginning, please read these instructions completely and carefully. • Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty. • All local and national codes and ordinances must be observed. Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSIZ223.1/NFPA-54 –latest edition.
Dimensions 30” W. Gas Rangetop 36” W. Gas Rangetop 29 35 (75-7/8 .9 ” cm ) (91-7/8 .1 ” cm ) 48” W. Gas Rangetop 47 (12 -7/8 1.6 ” cm ) Side View 28-9/16” (72.6 cm) 24-5/16” (61.8 cm) 1-5/8” (4.1 cm) 1” (2.5 cm) 8-1/8” (20.
Specifications VRT5 Series Gas Rangetops Description Overall width 30” W. Models 36” W. Models 48” W. Models 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) 47-7/8” (121.6 cm) Overall height (from bottom) To top of grate—9-1/4” (23.5 cm) To top of island trim—9-1/8” (23.2 cm) Additions to base height To top of backguard—add 8” (20.3 cm) To top of high shelf—add 23-1/2” (59.7 cm) Overall depth (from rear) To end of side panel—24-5/16” (61.8 cm) To end of landing edge—28-1/16” (71.
Clearance Dimensions •This rangetop may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets. IMPORTANT: The top of the side trim MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop. •The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm) side clearance from the rangetop to such combustible surfaces above the 36” (91.
Clearance dimensions The bottom of a standard hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the rangetop hood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood. Wo o d/C o Ov mpo erl sit ay e Note: Minimum clearance for back wall is 0” with backguard or high-shelf. ” 24 cm) .
Electrical & Gas Requirements Electrical Requirements WARNING There is no connection necessary beyond plugging the unit into a polarized, grounded, 120 volt, 60 Hz, 15 amp circuit. The minimum of 120 VAC is required for proper operation of gas ignition systems. This circuit MUST be grounded and properly polarized. The unit is equipped with a 16-SPT2 power cord.
General Information READ AND FOLLOW ALL WARNING AND CAUTION INFORMATION WHEN INSTALLING THIS APPLIANCE. WARNING Moving hazard •All openings in the wall behind the appliance and in the floor under the appliance should be sealed. •Do not obstruct the flow of combustion and ventilation air. To avoid risk of severe personal injury; this appliance requires two or more personnel while handling and moving. Possible use of appliance moving devices is recommended.
Final Preparation Some stainless steel parts may have a protective wrap, which must be peeled off. All stainless steel body parts should be wiped regularly with hot, soapy water at the end of each cooling period and with liquid cleaner designed for this material when soapy water will not do the job. If build-up occurs, DO NOT use steel wool, or abrasive cloths, cleaners, or powders.
Service & Registration If service is required, call your authorized service agency. Have the following information readily available. • Model number • Serial number • Date purchased • Name of dealer from whom purchased Clearly describe the problem that you are having.
Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-845-4641 or visit our website at vikingrange.