Clearance Dimensions (Proximity to Cabinets)
58” min.
(147.3 cm)
13” max.
(
33.0 cm)
12” min.
(30.5 cm)
18” min.
(45.7 cm)
3/8”
(0.95 cm)
36”
(
91.4 cm)
A
Range
Width
“A”
Dimension
36” 36” (91.4 cm)
48” 48” (121.9 cm)
• This range may be installed directly adjacent to
existing 36” (91.4 cm) high base cabinets.
IMPORTANT: The side panel MUST be
3/8” (.95 cm) above the adjacent base cabinet
countertop. This can be accomplished by raising
the unit using
the adjustment spindles on the legs.
• The range CANNOT be installed directly
adjacent to sidewalls, tall cabinets, tall
appliances, or other side vertical surfaces
above
36” (91.4 cm) high. There must be a
minimum of 12” (30.5 cm) side clearance
from the range to such combustible
surfaces above the 36” (91.4 cm) counter
height.
• Within the 12” (30.5 cm) side clearance
to combustible vertical surfaces above
36” (91.4 cm), the maximum wall cabinet
depth must be 13” (33.0 cm) and wall
cabinets within this 12” (30.5 cm) side
clearance must be
18” (45.7 cm) above the
36” (91.4 cm) high countertop.
• Wall cabinets above the range must be a
minimum of 58” (147.3 cm) above the range
cooking surface for the full width
of the range. This minimum height
requirement does not apply if a range hood is
installed over the cooking surface.
Note: Minimum clearance for back wall is 3/4”
(1.9 cm) with backguard or high-shelf.
Note: If a range hood is installed, wall cabinets above the
range have a different minimum clearance height.
Note: Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and not certified by CSA.
Clearances to non-combustible materials must be approved
by the authority having jurisdiction.
CAUTION
BURN HAZARD
To avoid risk of personal injury; the
use of cabinets for storage above
the appliance may result
in a potential burn hazard. Combustible items
may ignite, metallic items may become hot and
cause burns. If a cabinet storage is to be
provided the risk can be reduced by installing a
rangehood that projects horizontally a
minimum
5" (12.7 cm) beyond the bottom of cabinets.