Data Sheet

www.victronenergy.com
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | E-mail: sales@victronenergy.com
www.victronenergy.com
Liquid crystal display
For status monitoring and set-up
Load output
Over-discharge of the battery can be prevented by connecting all loads to the load output. The load output
will disconnect the load when the battery has been discharged to a pre-set voltage.
Some loads (especially inverters) can best be connected directly to the battery, and the inverter remote
control connected to the load output. A special interface cable may be needed, please see the manual.
The connect and disconnect voltages are adjustable.
Day/night timing of the load output
This option allows for a pre-set ON-time after dusk.
Programmable battery charge algorithm
Preprogrammed algorithms for AGM, GEL, Flooded or LiFePO4 batteries (with internal BMS only)
Two 5 Volt USB outputs
Maximum current (both outputs combined): 2A
BlueSolar PWM Charge Controller-LCD&USB 12/24V & 48V
BlueSolar Charge Controllers
LCD&USB 12/24-30 & 48-10/20/30
BlueSolar PWM
Charge Controller
12/24-5 12/24-10 12/24-20 12/24-30 48-10 48-20 48-30
Battery Voltage
12/24 V with automatic system voltage detection 48V
Rated charge current
5A 10A 20A 30A 10A 20A 30A
Automatic load disconnect
Yes
Maximum solar voltage
28V / 55V (1) 100V (1)
Self-consumption
< 10 mA
Load output Manual control + low voltage disconnect +timer
Protection Battery reverse polarity (fuse) Output short circuit Over temperature
Overload protection
Shut down after 60 s in case of 130% load
Shut down after 5 s in case of 160% load
Short circuit: immediate shut down
Grounding
Common positive
Operating temp. range -35 to +60°C (full load)
Humidity (non-condensing) Max 95%
BATTERY
Charge voltage 'absorption' Factory setting: 14,4V / 28,8V Factory setting: 57,6V
Charge voltage 'float' (2) Factory setting: 13,7V / 27,4V Factory setting: 54,8V
Low voltage load
disconnect
Factory setting: 11,2V / 22,4V Factory setting: 44.8V
Low voltage load reconnect
Factory setting: 12,6V / 25,2V Factory setting: 50,4V
USB
Voltage
5V
Current
2A (total from 2 outputs)
ENCLOSURE
Protection class
IP20
Terminal size
6 mm² / AWG10 16mm² / AWG6
Weight 0,15kg
0,3kg
Dimensions (h x w x d)
96 x 169 x 36 mm
(
3.8 x 6.7 x 1.4 inch
)
STANDARDS
Safety EN60335-1, IEC 62109-1
EMC EN 61000-6-1, EN 61000-6-3, ISO 7637-2
1) For 12V use 36 cell solar panels
For 24V use 72 cell solar panels or 2x 36 cell in series
For 48V use 2x 72 cell solar panels or 4x 36 cell in series
2) The controller switches to the lower float voltage level 2 hours after the
absorption voltage has been reached.
Whenever the battery voltage becomes lower than 13V, a new charge
cycle is triggered.