IND221 IND226 Industry Terminal User/Service Manual METTLER TOLEDO 182837 (2006-2-8)
PRECAUTIONS READ this manual BEFORE operating or servicing this equipment. WARNING DISCONNECT ALL POWER TO THIS UNIT BEFORE INSTALLING, SERVICING, CLEANING, OR REMOVING THE FUSE. FAILURE TO DO SO COULD RESULT IN BODILY HARM AND/OR PROPERTY DAMAGE. FOLLOW these instructions carefully. CAUTION SAVE this manual for future reference. OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES.
CAUTION BEFORE CONNECTING OR DISCONNECTING ANY INTERNAL ELECTRONIC COMPONENTS OR INTERCONNECTING WIRING BETWEEN ELECTRONIC EQUIPMENT, ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY (30) SECONDS BEFORE ANY CONNECTIONS OR DISCONNECTION’S ARE MADE. FAILURE TO OBSERVE THESE PRECAUTIONS COULD RESULT IN DAMAGE TO OR DESTRUCTION OF THE EQUIPMENT, OR BODILY HARM. CAUTION THE IND226 SOCKET-OUTLET SHALL BE INSTALLED NEAR THE EQUIPMENT AND SHALL BE EASILY ACCESSIBLE.
Contents 1.0 1.1 1.2 1.3 1.4 2.0 2.1 2.2 2.3 2.4 3.0 3.1 3.2 3.3 4.0 4.1 4.2 4.3 5.0 5.1 5.2 5.3 Overview................................................................................................................................. 1 Specification ....................................................................................................................... 1 Main functions ....................................................................................................................
1.0 Overview 1.1 Specification z z z z z z z z z z z z z z z 6 digits 1.2” large green LED display. Robust long life. 6 Function keys, Simple and easy. IND221: Plastic, Protection IP54. IND226: Stainless steel, Protection: IP69K. Executive voltage:+5VDC. Load Cell capability: Maximum 4-350ohm analog load cell. Zero signal input ranges: 0~5mV. SPAN signal input ranges: 1~10mV. Resolution: 1,000,000. Increments: 1,000 ~ 30,000 A/D Rates: 27 /seconds. Working voltage: AC87~264VAC, 0.
1.3 Dimensions 129.1mm 1.5 90° 150mm 45° 136.8mm 220mm IND221 220mm 90mm 150mm 132mm 66mm IND226 1.
2.0 Install This part will talking about the Installation for IND221 and IND226. Please read this chapter carefully before install. 2.1 Open the package Open the package, And check all the parts with the checklist. Make sure no part was damaged and missing. Remove the terminal from its protective package, . 2.2 Electronic Connect 2.2.1 Open the terminal The IND221 terminal use 4 screws to lock the front cover.
Pin 5 - -SIG Pin 6 - -SEN Pin 7 - -EXC For 4 wires load cell, you should short the W1 two pins, and short the W2 two pins in PCB. IND221 use PG9 cable bush grip, the allow cable diameter is 4 to 9mm. IND226 use PG11 cable bush grip, the allow cable diameter is 5 to 10mm. We recommend use CMX or CM cables for load cell connect. The cable information: Type: CMX, CM Parameter: 6x0.2mm2 Voltage: Max. 380V Temperature range: -30~+80° Cable diam: 6.1±0.15mm. Isolation material: UBEC180 polyethylene.
2.3 Lead seal After setup and calibration you can seal the terminal. IND221: IND226: 2.4 Battery Pack Option 2.4.
2.4.2 Recharge Battery When the low battery cursor light on red color, it means the battery voltage is low, you can still continuous your work for about one hour.. When the low battery cursor flash on red color, it means the battery voltage is too low, you should charge the battery immediately. Plug the AC power line will automatic recharge the battery, and the low battery cursor will light on green color. Normally the charge time is about 12 hours.
3.0 Operation 3.1 Operation HMI METTLER TOLEDO Function Motion Net Under OK Over 0 On/Off Zero NET T Tare >|1|< >|2|< F Function lb kg Battery Units Ranges C Clear Print “Under OK Over” is use for check weighing. You can stick ”Count APW PCS” label for counting function. 3.2 Basic function operation 3.2.1 On/Off key Hold the key 2 seconds, All display segments will light. The terminal will show software part number [178037] [L 1.00]. Then the terminal will show the normal weight.
3.2.4 Clear Clear the tare, the display will go back to gross mode. C 3.2.5 Print Print the current weight. 3.3 Expand functions 3.3.1 X10 Function F2.1 is set to ÑÖUL10 - x10 function. F Under OK Over NET >|1|< >|2|< lb Press kg key, The terminal will show more accuracy weight for 20 seconds. Under OK Over NET >|1|< >|2|< lb Print is forbidden in this mode. kg 3.3.2 Unit switch F2.
The terminal show the old target weight.. Under OK Over NET >|1|< >|2|< lb kg If F2.2.2 is set to WEIGHt- Get target weight from weighing. Then you can put the target Under OK Over NET >|1|< >|2|< lb kg F weight in scale platform. Press key to set new target weight. If F2.2.2 is set to MAnUAL- Manually set the target weight. You can input target weight directly, then press Enter to confirm. Operation: Current weight less than target weight and over tolerance.
directly, then press Enter to confirm. Operation: Current weight less than target weight and over tolerance. Under OK Over NET >|1|< >|2|< lb kg Current weight near the target weight and within tolerance. Under OK Over NET >|1|< >|2|< lb kg Current weight larger than target weight and over tolerance. Under OK Over NET >|1|< >|2|< lb kg 3.3.4 Counting Function F2.1 is set to Count - Counting function. Stick “Count APW PCS” label at “Under Display Mode switch: OK Over” position.
Display mode will go back to counting PCS mode. APW Enhancement: If F2.3 = On, Enable APW enhancement function. Then after the pieces number increased, the terminal will automatically adjust the average weight to get more accuracy pieces number. 4.0 Setup 4.1 Enter Setup Hold key 2 seconds, terminal will show [MAStEr] . Ask for password: T 0 0 T (Can setup every parameters). Supervisor password: 0 Operatorpassword: Press 0 0 (Can only setup F2). to confirm.Terminal will show [SEtUp] .. If F1.
F Digits Input: Press key to edit current number. Change input cursor to left. C Press key to clear current number. T 0 Press key to decrease. Press Press to confirm.. key to increase. 4.3 Setup Detail F1 – Scale F1.1 – Approval Selection: no(Factory default) OIÑÖL ntEP otHEr - none - OIML - NTEP - Other approval F1.2 – Scale Capacity & Increments F1.2.1 – Units Selection: 1 - kg (Factory default) 2 - lb F1.2.2 – Ranges Selection: 1 r – 1 Range (Factory default) 2 r - 2 Ranges F1.2.
F1.3 – Calibration F1.3.1 GEO Adjustment Selection: 0…31 (Factory default16) F1.3.2 – Linearity Selection: On OFF - Enabled - Disabled (Factory default) F1.3.3 – Calibration z If F1.3.2 is set to On [E SCL] Empty scale. Remove any load from scale platform, then press Enter to confirm. Terminal will count down from[10 CAL] to [ 0 CAL]. [FULL Ld] Add full load. Add load on the scale platform, then press Enter. [000000] Input weight number, then press Enter to confirm.
F1.5.1 –Auto Tare Selection: On,OFF(Factory default) F1.5.2 – Auto Clear Selection: On,OFF(Factory default) F1.5.3 – Tare Interlock Selection: On,OFF(Factory default) F1.5.4 – Auto Tare threshold. Selection: 0 ~ FS(Factory default10d) F1.5.5 – Auto Tare reset threshold Selection: 0 ~ FS(Factory default10d) F1.6 – Digital filter F1.6.1 – Digital filer Selection: Lo - Low ÑÖEd (Factory default) - Middle HIGH - High F1.6.2 – Motion range Selection: 0.5d(Factory default),1d,3d F1.
Selection: 0…FS(Factory default 10d) F2.2.4 – Minus Tolerance Selection: 0…FS(Factory default10d) F2.3 – APW Enhancement(F2.1 is set to Counting) Selection: On,OFF(Factory default) F2.10 – F2 reset to Factory default All F2 parameters will be set to Factory default. F3 – Terminal F3.1 – Display F3.1.1 – Timeout Selection: 0, 10~999 seconds (Factory default 60s) function. 0 will disabled this F3.1.
F4.2.2 – Print format Selection: StAndr(Factory default)- Standard OVEr - Over/Under Count - Count F4.2.3 – Print languages Selection: EnG(Factory default) CHn - English - Chinese F4.2.4 – Add Line Feed Selection: 0~9 (Factory default 3) F4.2.5 – Auto print threshold Selection: 0 ~ FS (Factory default10) F4.2.6 – Auto print reset threshold Selection: 0 ~ FS (Factory default10) F4.3 – Com1 F4.3.1 – Baud rate Selection: 1200, 2400, 4800, 9600(Factory default),19200 F4.3.
F5.1.5 – Full load Counts F5.2 – Keypad test Terminal show ”PrESS “, You can press Zero, Tare, F, Clear, Print. On/Off key to exit.. F5.3 – Display test All display segments will light. F5.4 – Display internal resolution Display internal resolution. F5.5 – COM1 test Connect COM1 to computer to test COM1.. F5.6 – Print setup Print all setup parameters.. F5.10 – Reset all parameters to Factory default Reset all F1~F4 Reset all parameters to Factory default. Not include calibration values.
5.0 Terminal Maintenance 5.1 Daily maintenance Main PCB: Cal switch S1 U8 U7 J1 DC in J7 Keypad 1 AC out J8 4 wire load cell connectors Software download 1 Fuse J3 w3 W1 J2 W2 F1 J6 1 1 1 Load cell AC input RS232 COM1 J1 - Keypad connector. J2 - Load cell connector. J3 - RS232 connector . J6 - AC power in, 87~264VAC. J7 - DC power in, from rechargeable PCB and Dry battery. J8 - AC power out, to rechargeable PCB. W1 ,W2 - 4 wires load cell connectors. W3 - Software download.
{||||} Over load, more than 9d above Reduce the load scale capacity <____> Under Zero 5d Zero the scale {|no|} Over the zero range Remove the load --no-- Key forbidden Check setup Err EEPROM verify error Reset the terminal <_no_> 3 Err 35 Scale is in calibration Err 4 Samples number too small.