Specification Sheet

JCH/A1 Series Equipped with LED lighting. Not available with heat lamps. Shown with optional duct
cover (sold separately). Optional duct covers available in standard and custom sizes.
DESIGNER SERIES WALL MOUNT RANGE HOOD
U
L
CUS
R
OPTIONAL
DUCT
COVER
Centerline
Of Hood
Wall Side
Electrical (2)
10" Outlet
Centered On
Hood Top
12 ⁄” 9 ⁄”
1 ¾”
Wall Side
7"
Electrical (2)
Centerline
Of Hood
12" Outlet
Centered On
Top Of Hood
1 ¾”
16 ½”
5 ½”
1 ¾”
Electrical
1 ¾”
Centerline
of Hood
8” Outlet
Vent
Holes
5 ¼”5 ½”
Wall Side
36"
30"
*Recommended mounting
height is for optimum
performance.
Recommended
Mounting Height
Connection Diagrams (36" - 48" Widths)
Connection Diagram (48" - 60" Widths)
Connection Diagram (54" - 66" Widths)
B100 Single Blower
(Top View)
(Front View) B200 Dual Blower
(Top View)
(Front View)
900 CFM B200 Dual & B100 Single Blower
(Top View)
VP562 Standard Transition
Installed (Front View)
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Standard Transition
Installed (Front View)
Electrical/Mechanical Specications For Blower Units
Model Volts Amps Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B100 Single 115 2.5 60 1550 300 450 273 245 225 6" (28 in.
2
) 5.4
B200 Dual 115 4.0 60 1550 600 900 531 480 430 8" (50 in.
2
) 6.5
B200 Dual & B100 Single 115 6.0 60 1550 900 1350 804 725 655 VP562: 10" (79 in.
2
) 6.3
Two B200 Duals 115 7.5 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.
2
) 6.6
Hood is available with LED lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efcientlythanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0516A
10” Round 10” Round
8” Round
17 ½”
2”
8” Round 6” Round
12” Round 12” Round
16 ½”
8” Round 8” Round
8” Round
3”
VP562 Standard Transition
Included
VP563 Standard Transition
Included
 














6” Outlet
Vent
Hole
3 ¼”
Electrical
Centerline
of Hood
Wall Side
1 ¾”
1 ⁄”5 ¼”