Product Specifications

VP562/VP563
transition
centers outlet
over top of hood
BHPSLD LINER Equipped with LED lighting. Not available with heat lamps.
WALL MOUNT LINER INSERT SPECIFICATIONS
*Recommended mounting
height is for optimum
performance.
Connection Diagram (46 3/8” - 58 3/8” Widths)
Connection Diagram (52 3/8” - 64 3/8” Widths)
600 CFM B200 Dual Blower
(Top View)
900 CFM B200 Dual & B100 Single Blower
(Top View)
1200 CFM Double B200 Dual Blowers
(Top View)
Electrical
1 ¾”
Centerline
of Hood
8” Outlet
Vent
Holes
5 ¼”5 ½”
Wall Side
8” Outlet
6” Outlet
5 ¼”
Wall Side
Vent
Holes
Centerline
of Hood
Electrical (2)
5 ½”
7 ⁄”
1 ⁄”
7 ⁄”
1 ¾”
11” 11”
5 ½” 5 ½”
Wall Side
5 ¼”
1 ¾”
Electrical (2)
8” Outlet
Vent
Holes
8” Outlet
Centerline
of Hood
10” Round 10” Round
8” Round
17 ½”
2”
8” Round 6” Round
12” Round 12” Round
16 ½”
8” Round 8” Round
8” Round
3”
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
U
L
CUS
R
VP562: 10”
VP563: 12”
Connection Diagrams (28 3/8” - 52 3/8” Widths)
Recommended
Mounting Height*
BHPSLD
Electrical/Mechanical Specications For Blower Units
Model Volts Amps Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B100 Single 115 2.5 60 1550 300 450 273 245 225 6" (28 in.
2
) 5.4
B200 Dual 115 4.0 60 1550 600 900 531 480 430 8" (50 in.
2
) 6.5
B200 Dual & B100 Single 115 6.0 60 1550 900 1350 804 725 655 VP562: 10" (79 in.
2
) 6.3
Two B200 Duals 115 7.5 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.
2
) 6.6
Hood is available with LED lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efcientlythanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1120A












300 CFM B100 Single Blower
(Top View)
6” Outlet
Vent
Hole
3 ¼”
Electrical
Centerline
of Hood
Wall Side
1 ¾”
1 ⁄”5 ¼”

Summary of content (1 pages)