Instruction Manual

Dynamic behaviour output
Run-up time
approx. 10 s
90 %
100 %
10 %
t
t
T
A
t
t
S
2
1
Fig. 28: Sudden change of
the process variable, dead time t
T
, rise time t
A
and step response time t
S
1 Process variable
2 Output signal
Dead time 150 ms
Rise time 100 ms (10 90 %)
Step response time 250 ms (ti: 0 s, 10 90 %)
To this amounts the reaction time of the isolatng system. This time varies from values < 1 s with
compact isolating diaphragms up to several seconds with capillary systems.
Example: Flange isolating diaphragm DN 80, lling silicone oil KN 2.2, capillary length 10 m,
measuring range 1 bar
Process temperature Reaction time
40 °C approx. 2 s
20 °C approx. 3 s
-20 °C approx. 11 s
Damping (63 % of the input variable) 0 999 s, adjustable
Input variable
Adjustment
Adjustment range of the min./max. adjustment relating to the nominal measuring range:
- percentage value -10 110 %
- pressure value -20 120 %
54 VEGABAR 61 Probus PA
10 Supplement
28251-EN-081209