Technical data
346 Keysight InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
20 :MEASure Commands
for <meas_spec> = THResholds and <threshold mode> = PERCent:
THR,PERC,<upper>,<middle>,<lower><NL>
<upper>, <middle>, <lower> ::= A number specifying the upper, middle,
and lower threshold percentage values
between Vbase and Vtop in NR3 format.
for <meas_spec> = THResholds and <threshold mode> = ABSolute:
THR,ABS,<upper>,<middle>,<lower><NL>
<upper>, <middle>, <lower> ::= A number specifying the upper, middle,
and lower threshold voltages in NR3
format.
for <threshold spec> = STANdard:
THR,PERC,+90.0,+50.0,+10.0
See Also • "Introduction to :MEASure Commands" on page 340
• ":MEASure:DELay" on page 347
• ":MEASure:SOURce" on page 361
• ":CHANnel<n>:RANGe" on page 233
• ":CHANnel<n>:SCALe" on page 234
• ":CHANnel<n>:PROBe" on page 227
• ":CHANnel<n>:UNITs" on page 235