Specification

SUBMITTAL SHEET
USG
R o o fi n g
Solutions
USG
Interior
Panel &
Finishing
Solutions
USG SHEETROCK
®
BRAND
FIRECODE
®
X PANELS
The original 5/8 in. Type X wallboards for interior walls and ceilings
Provide additional fi re resistance over regular panels
Underwriters Laboratories Inc. (UL) Classifi cation as to fi re resistance, surface-burning
characteristics and noncombustibility
Comply with ASTM C1396 physical properties for 5/8 in. Type X gypsum wallboard
Achieved GREENGUARD Gold Certi cation and quali es as a low VOC emitting material
(meets CA 01350)
USG Sheetrock® Brand Firecode® X Panels (UL Type SCX) are 5/8 in. Type X panels that feature
a fi re-resistant gypsum core encased in 100% recycled face and back papers that form a high
strength composite design. The natural fi nish face paper is folded around the long edges to
reinforce and protect the core, and the ends are cut square and even. The long edges of panels are
tapered, allowing joints to be reinforced and concealed with USG Sheetrock® Brand joint treatment
systems. USG Sheetrock® Brand Firecode® X Panels are UL Classi ed for fi re resistance and can
be used in any UL Design where Type SCX panels are listed. The UL Type Designation is printed
with nonbleeding ink on the face along the long edge of each panel for easy identifi cation by
building inspectors.
Commercial or residential applications where 5/8 in. Type X panels are required
New or repair and remodel construction
Protection of load-bearing and non-load-bearing wood- or steel-framed fi re-rated walls
1. Avoid exposure to sustained temperatures exceeding 125 °F (52 °C).
2. Avoid exposure to excessive, repetitive or continuous moisture before, during and after
installation. Eliminate sources of moisture immediately.
3. Maximum frame spacing for walls is 24 in. OC.
4. Must be stored o the ground and under cover in accordance with Gypsum Association's
Handling and Storage of Gypsum Panel Products (GA-801-07).
5. Not for load-bearing design and not a structural panel.
Maximum Frame Spacing Drywall Construction
Direct Application Panel Thickness Location Application Method
1
Maximum Frame Spacing OC
Single-layer 5/8 in. (15.9 mm) Ceilings Perpendicular 24 in. (610 mm)
Sidewalls Parallel or perpendicular 24 in. (610 mm)
Double-layer 5/8 in. (15.9 mm) Ceilings Parallel or perpendicular 24 in. (610 mm)
2
Sidewalls Perpendicular 24 in. (610 mm)
2
Notes:
1. Long edge position relative to framing.
2. Maximum spacing 16 in. OC if fi re rating required.
DESCRIPTION
INTENDED FOR
LIMITATIONS
INTERIOR INSTALLATION,
FINISHING AND DECORATING
INSTALLATION