Instructions / Assembly
Universal Walk-In Bathtubs 5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-360-4454 FAX: 866-560-1060 www.universaltubs.com
Page 11
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
CONNECTING THE AUTODRAIN
HIGH-SPEED AUTODRAIN FOR SOAKING TUB AND/OR AIR SYSTEM
• Drain System requires the connection to a minimum 1 ½ sanitary drain line.
• Use UPC Approved PVC Glue, primer, and Schedule 40 1 ½ ’ pipe.
• Do not change or modify the location and or piping of the Back Flow Preventer.
• The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.
• Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit.
• Glue the High-Speed Autodrain Fittings, pipe and drain overflow assembly to the sanitary drainage pipe.
NOTE: WATER TIGHT INSTALLATION OF THE WASTE/ OVERFLOW IS THE INSTALLER’S RESPONSIBILITY. DRAIN LEAKAGE IS
EXCLUDED FROM THE UNIVERSAL TUBS WARRANTY OF THIS PRODUCT.
NOTE: WE HAVE TAKEN RESPONSIBLE PRECAUTIONS TO ENSURE THE HIGH-SPEED AUTODRAIN IS SUITABLE FOR
RESIDENTIAL PLUMBING. IT IS RESPONSIBILITY OF THE INSTALLER TO INSURE THE SANITARY SYSTEM IS ACCEPTABLE
FOR THE USE OF THE HIGH-SPEED AUTODRAIN. WE DO NOT ACCEPT RESPONSIBILITY FOR DAMAGE ARISING FROM THE
USE OF THE HIGH- SPEED AUTODRAIN.*
*-Ensure compliance with local plumbing codes.
110Vt-60hz pump (15 Amp Circuit)
overflow
drain cable
drain cable
drain
drain shoe
sanitary tee
drain tee
90° Elbow
reducer 1 1/2-1”
air button (on/off)
back flow preventer
air button (on/off)
diverter valve
jets
overflow
drain cable
drain cable
drain
drain shoe
sanitary tee
drain tee
90° Elbow
reducer 1 1/2-1”
back flow preventer
110Vt-60hz pump (15 Amp Circuit)
SOAKER & AIR AUTODRAIN CONNECTION HYDRO & DUAL AUTODRAIN CONNECTION