Instructions / Assembly

Universal Walk-In Bathtubs 5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-360-4454 FAX: 866-560-1060 www.universaltubs.com
Page 11
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
CONNECTING THE AUTODRAIN
HIGH-SPEED AUTODRAIN FOR SOAKING TUB AND/OR AIR SYSTEM
Drain System requires the connection to a minimum 1 ½ sanitary drain line.
Use UPC Approved PVC Glue, primer, and Schedule 40 1 ½ ’ pipe.
Do not change or modify the location and or piping of the Back Flow Preventer.
The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.
Dry fit the drain overflow assembly to the sanitary drainage pipe and check for proper fit.
Glue the High-Speed Autodrain Fittings, pipe and drain overflow assembly to the sanitary drainage pipe.
NOTE: WATER TIGHT INSTALLATION OF THE WASTE/ OVERFLOW IS THE INSTALLER’S RESPONSIBILITY. DRAIN LEAKAGE IS
EXCLUDED FROM THE UNIVERSAL TUBS WARRANTY OF THIS PRODUCT.
NOTE: WE HAVE TAKEN RESPONSIBLE PRECAUTIONS TO ENSURE THE HIGH-SPEED AUTODRAIN IS SUITABLE FOR
RESIDENTIAL PLUMBING. IT IS RESPONSIBILITY OF THE INSTALLER TO INSURE THE SANITARY SYSTEM IS ACCEPTABLE
FOR THE USE OF THE HIGH-SPEED AUTODRAIN. WE DO NOT ACCEPT RESPONSIBILITY FOR DAMAGE ARISING FROM THE
USE OF THE HIGH- SPEED AUTODRAIN.*
*-Ensure compliance with local plumbing codes.
110Vt-60hz pump (15 Amp Circuit)
overflow
drain cable
drain cable
drain
drain shoe
sanitary tee
drain tee
90° Elbow
reducer 1 1/2-1”
air button (on/off)
back flow preventer
air button (on/off)
diverter valve
jets
overflow
drain cable
drain cable
drain
drain shoe
sanitary tee
drain tee
90° Elbow
reducer 1 1/2-1”
back flow preventer
110Vt-60hz pump (15 Amp Circuit)
SOAKER & AIR AUTODRAIN CONNECTION HYDRO & DUAL AUTODRAIN CONNECTION