WALK-IN TUB MANUAL INSTALLATION & OPERATING INSTRUCTIONS MediTub S a f e t y M e e t s L u x u r y OPERATING INSTRUCTIONS l 30x53 MODELSInstructions ation 2646 2653 2952 2952WCA 3053 3054 Page 1 3060 3060BL 3060SI 3060WCA 3260 3660 INSTALLATION & OPERATING INSTRUCTIONS W h e r e
WALK-IN TUB MANUAL TABLE OF CONTENTS TABLE OF CONTENTS THANK YOU FOR CHOOSING US!................................................................................. 2 CONTACT INFORMATION............................................................................................ 2 PRODUCT REGISTRATION*........................................................................................ 3 SAVE THIS MANUAL!................................................................................................
WALK-IN TUB MANUAL OPERATING INSTRUCTIONS Page 2
WALK-IN TUB MANUAL THANK YOU & CONTACT INFORMATION THANK YOU FOR CHOOSING US! Our mission is to help you maintain independence over essential bathing needs and improve the quality of life! This is designed to be the most accessible, most comfortable walk-in bathtub on the market today! Until recently, if you have difficulty getting in and out of a bathtub, it was almost impossible for you to take a bath. We specialize in accessibility and security.
WALK-IN TUB MANUAL PRODUCT REGISTRATION PRODUCT REGISTRATION* * To ensure that your warranty is registered with us, complete, sign and return this registration card within 30 days of the purchase. NOTE:Your warranty will not be recognized by us unless this card is fully completed and returned to: 5701 NW 35 Avenue Miami, FL 33142.
WALK-IN TUB MANUAL SAVE THIS MANUAL SAVE THIS MANUAL! READ THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING THE PRODUCTS. FAILURE TO DO SO COULD RESULT IN AN IMPROPER INSTALLATION AND COULD VOID THE WARRANTY. RESPONSIBILITY OF THE INSTALLER THE INSTALLER MUST INSPECT AND WATER-TEST THE PRODUCT PRIOR TO INSTALLATION TO ENSURE THE UNIT IS FREE OF DEFECT OR DAMAGE. IN THE EVENT OF A PROBLEM, THE UNIT MUST NOT BE INSTALLED.
WALK-IN TUB MANUAL IMPORTANT SAFETY INSTRUCTIONS! INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS WARNING – WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL INSTRUCTIONS. DANGER: TO REDUCE THE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE THIS UNIT UNLESS THEY ARE CLOSELY SUPERVISED AT ALL TIMES. OPERATING INSTRUCTIONS USE THIS UNIT ONLY FOR ITS INTENDED USE AS DESCRIBED IN THIS MANUAL.
WALK-IN TUB MANUAL CLEANING AND MAINTENANCE Pump and pipe circulation systems should be flushed before first use and on a monthly basis when product is under normal use. WARNING! NEVER OPERATE THE WHIRLPOOL JETS WHEN TUB IS EMPTY. Below are the recommended procedures for cleaning: • Do not run whirlpool dry.
WALK-IN TUB MANUAL UNPACKING UNPACKING THE UNIT INSPECTING THE PACKAGING Inspect the carton. If any damages are noted, photograph the damaged area(s) and notify the deliverer/carrier. LIFTING / TRANSPORTING Never lift the walk-in bathtub by the plumbing. Doing so may result in damaging the plumbing and causing a leak. INSPECTING THE UNIT assumed to be installation related if not reported at this point.
WALK-IN TUB MANUAL SAFETY PRE-INSTALLATION* * All Walk-In Bath Tubs are 100% water tested at the factory certified to be free of leaks.Transportation and mishandling may cause leaks. It is necessary to test the bathtub while there is access to all sides of the bathtub. READ AND FOLLOW ALL INSTRUCTIONS • Place the tub on a completely flat surface in an area where it may be drained after testing. • Close the drain and fill the tub until it is above the highest jet.
e t y M e e t s L u x u r y WALK-IN TUB MANUAL INSTALLATION PREPARATION INSTALLATION PREPARATION 1. Check the floor area where the tub is to be installed. • a. Clean area of any debris or trash. • b. Use a 5 or 6-foot level and determine if the floor is level. If the floor is not level, adjust all 6 leveling feet to perfectly level the tub.
WALK-IN TUB MANUAL ELECTRICAL PREPARATION ELECTRICAL PREPARATION All electrical wiring must be installed in accordance with the National Electrical Code and with all local codes. All wiring shall be done by a qualified electrician. Run one, two or three branch circuits (as required) from the main electrical service panel to the pump area of the framing structure to provide power to the unit. Electrical components have specific wiring requirements.
WALK-IN TUB MANUAL INSTALLATION PROCEDURES INSTALLATION PROCEDURES WARNING! WHEN USING ELECTRICAL PRODUCTS, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: DANGER! RISK OF ELECTRIC SHOCK. CONNECT ONLY TO CIRCUIT PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI). OPERATING INSTRUCTIONS INSTALL THIS UNIT IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE, PART I. INSTALLER CONFORMEMENT AU CODE CANADIEN DE L’ELECTRICITE, PREMIERE PARTIE (CSA C22.2 NO. 218.
WALK-IN TUB MANUAL INSTALLATION INSTRUCTIONS DRAIN CONNECTION To ensure safe transit for your walk-in tub, the overflow drain components are not connected to the unit during the process of production. The following instructions are provided for installation purposes: Your walk-in tub is supplied with a 1 ½” drain pipe overflow.
WALK-IN TUB MANUAL INSTALLATION INSTRUCTIONS CONNECTING THE AUTODRAIN HIGH-SPEED AUTODRAIN FOR SOAKING TUB AND/OR AIR SYSTEM INSTALLATION INSTRUCTIONS • Drain System requires the connection to a minimum 1 ½ sanitary drain line. • Use UPC Approved PVC Glue, primer, and Schedule 40 1 ½ ’ pipe. • Do not change or modify the location and or piping of the Back Flow Preventer. • The sanitary tee is installed directly above the drain tee with clearance not greater than 1’’.
WALK-IN TUB MANUAL INSTALLATION INSTRUCTIONS INSTALLATION AND EXTENSION PANELS ASSEMBLY & PLACEMENT Connect the two panels using pre-drilled holes: Top pannel Inner flange Mortar Side pannel INSTALLATION INSTRUCTIONS Bathroom (Waterproof) Sheetrock Wall Tile Silicone 2-piece extension panels Screw Molded flange to bolt unit to wall Custom-built wall section(s) for open ends or install against corners of full wall Page 15
WALK-IN TUB MANUAL INSTALLATION INSTRUCTIONS FAUCET INSTALLATION diverter spout hot control handle fixing nut shower head cold control handle fixing nut INSTALLATION INSTRUCTIONS rubber washer fiber washer fixing nut gasket hot water valve body cold water steel braded 19” hose Page 16 local water line steel braded 19” hose 72” shower hose
WALK-IN TUB MANUAL OPERATING SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS WARNING! RISK OF PERSONAL INJURY: • Use this unit for its intended use as described in this manual. DO NOT use attachments not recommended by the manufacturer. • To avoid injury, exercise caution when entering or exiting your walk-in tub.
WALK-IN TUB MANUAL The unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, there may be a ground current flowing, indicating the possibility of an electric shock. Do not use this massage bathtub.
WALK-IN TUB MANUAL OPERATING INSTRUCTIONS When entering a our walk-in tub, be sure to close the door, placing the handle in the down position. Before activating any of the jetting controls, you must first fill the bath to a water level at least 2 inches above the highest jet placement. Do not put weight on the door when entering and exiting the tub. It is recommended to leave the door in the open position when the tub is not in use.
WALK-IN TUB MANUAL PURGE CYCLE All air blowers are equipped with a purge cycle to remove residual water from the lines. The cycle will begin approximately 30 minutes after the unit is turned off and will continue for 1 - 2 minutes. WARNING: DO NOT PUSH THE BUTTON ONCE THE CYCLE BEGINS. DOING SO WILL CAUSE THE BLOWER TO RESTART ONCE THE PURGE CYCLE ENDS. WARNING: DO NOT INTERRUPT THE PURGE CYCLE BY UNPLUGGING OR SHUTTING DOWN THE AIR SYSTEM.
WALK-IN TUB MANUAL TUB CONTROLS 1 HYDRO CONTROL (PUMP) Used to turn the water jets ON and OFF. 1 2 AIR CONTROL (BLOWER) Used to turn the air jets ON and OFF. 2 If a 3-SPEED Blower (Optional) system is installed. 1st Press: Blower starts at MAX speed 2nd Press: Blower at MED speed 3rd Press: Blower at MIN speed 4th Press: Blower turns OFF 3 OPERATING INSTRUCTIONS 4 3 CHROMO CONTROL (LIGHT) Used to turn the chromotherapy lights ON and OFF.
WALK-IN TUB MANUAL WARRANTY WARRANTY his 10-year warranty is extended to the first user to be free from defects in workmanship and material under normal use and conditions for a period of 10 years from the date of the original purchase. This warranty relates to the bathtub shell, frame and finish. The finish’s warranty does not apply to fading, cracking, delaminating or blistering due to excessive wear, sun fading or scouring due to cleaning. Different warranty periods apply.
WALK-IN TUB MANUAL WARRANTY retailers, distributors or contractors. Manufacturer does not warranty the installation, plumbing or electrical related connections, of any of our products including Walk-In Baths, shower pans or shower stalls. Improper or negligent installation of the product or other components, alteration made of, or alterations or medications to the system, may cause the product or the system to malfunction. Such problems are not covered by warranty.
WALK-IN TUB MANUAL RETURN POLICY RETURN POLICY We are committed to providing premium customer service. In the event that a product must be returned due to reasons other than defects, as mentioned in the warranty, the following procedures apply: Requests for returns and/or exchanges must be made within 30 days of receipt of product. The product must be in its original packaging and received at our facility in saleable condition.
WALK-IN TUB MANUAL PRODUCT REGISTRATION PRODUCT REGISTRATION CARD The completed card should be cut out or copied, completed, and mailed to: 5701 NW 35 Avenue Miami, FL 33142 PRODUCT REGISTRATION OPERATING INSTRUCTIONS Product Registration Card Name...................................................................................... Address............................................................................................................................ City....................................
WALK-IN TUB MANUAL OPERATING INSTRUCTIONS Page 26
WALK-IN TUB MANUAL OPERATING INSTRUCTIONS Page 27
WALK-IN TUB MANUAL INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS