Installation Guide

Silent
Test/Silence
Button Has
Been Pressed
Blinks On in sync
with Horn
Nuisance
Alarm
3 Beeps,
2 second pause,
Repeat
If there is no hazard present, verify the alarm is mounted
in the correct location (see User's Manual, "AVOID THESE
LOCATIONS" section). Reset alarm as instructed below.
Alarm needs to
be reset due
to varying
conditions/
previous alarms
Off
HORN
ALARM AUDIBLE & VISUAL SIGNALS
New - Out
of Package
CONDITION
QUICK REFERENCE GUIDE / OPERATIONAL SUMMARY
Low Battery 2 chirps
approx every
60 seconds
Deactivate alarm (see User's Manual "ALARM DEACTIVATION"
section). Replace alarm immediately.
Blinks On once
approx every
2 minutes
RECOMMENDATION
DC Power is
Present
Silent Blinks On once
approx every
2 minutes
Silent
To activate the alarm, remove the pull tab. The alarm will sound
one long beep to conrm it is powered up. Press the Test/Silence
button. Test the alarm following installation and weekly thereafter.
The built-in test switch accurately tests the alarm operation as
required by ANSI/UL217 Standards for Safety. If, at any time,
you test the alarm and it does not perform as described, replace
it immediately.
The alarm is operating properly.
RED LED
3 beeps,
2 second pause,
Repeat
The alarm is operating properly.
Blinks On in sync
with Horn
Alarm Reset - Press and Hold the Test/Silence button for approximately 10 seconds and release. This will clear the Silence
Feature and Alarm Origination.
THIS PRODUCT CONFORMS TO UL STANDARD 217 FOR SAFETY
3 Beeps,
2 second pause,
Repeat
Blinks On in sync
with Horn
If hazard is identied, please take all precautions if an alarm
sounds by calling an Emergency Service and getting out of
the home.
3 Beeps,
2 second pause,
Repeat
Silence Feature is activated by pressing and releasing the Test/
Silence button on the initiating alarm while in alarm condition.
Silence mode will last for approx 10 minutes with the red LED
blinking once approx. every 10 seconds.
Blinks On in sync
with Horn
Alarm has
Sensed Smoke
Blinks On once
approx every
2 minutes
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
Silent
(alarmed
previously)
QUICK FIND
®
Alarm Origination - The QUICK FIND
®
feature
will allow you to locate the originating alarm (once the alarms
have stopped sounding). To initiate QUICK FIND
®
, press the
Test/Silence button on any alarm. After releasing the button,
the originating alarm will continue to sound for approx 60
seconds. It is necessary to test each alarm to determine the
originating alarm.
Alarm has
Previously
Sensed Smoke
To reset the alarm, hold the Test/Silence button for approx 10
seconds and release. This will clear Alarm Origination. Reset
alarm after every alarm event.
Blinks On once
approx every
2 minutes
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
Originating
Smoke Alarm
Product
End-of-Service
Life Notication
2 chirps
approx every
60 seconds
Blinks On once
approx every
2 minutes
Deactivate alarm (see "ALARM DEACTIVATION" section in
User's Manual). Replace alarm immediately.
Page 8
MODEL MI3050SB and MI3050S
If you have any additional questions about the operation of this alarm,
please contact our Customer Service Department at 1-800-390-4321,
and we will gladly assist you.

Summary of content (1 pages)