Owner`s manual
106
• Edit Frequency — Enter the desired frequency that the scanner should
monitor for the tone-out.
• Set Modulation — Set the modulation type for the paging signal. Next
choose the modulation setting:
• Auto — The scanner uses the default modulation for the frequency band. If
the default modulation is AM, WFM, or FMB, the modulation operates as
FM.
• NFM — The scanner uses NFM modulation.
• FM — The scanner uses FM for the frequency band. This is the default
setting.
• Set Attenuator — Press
F then turn the Scroll Control to
select On or Off.
Set Tone — Sets the audio tone frequency for the page. Then choose the Tone
setting.
• Edit Tone A — Set the audio frequency for Tone A
• Edit Tone B — Set the audio frequency for Tone B
Notes:
• For two-tone pages, enter a value for A and B.
• For one-tone pages using short tones of less than 3.75 seconds, enter the tone
value for A, and 0 (zero) for B.
• For long-tone pages, such as group pages of more than 3.75 seconds, enter 0
(zero) for A and the tone value for B.
Set Delay Time — Sets the time the scanner remains in monitor mode after the
scanner receives a page and the carrier drops.
• 1-5 sec — the scanner resumes standby mode after the carrier drops and
the selected time expires.
• Infinite — you must press [HOLD/RESUME] after a page to resume
standby mode.
• Off — the scanner resumes standby as soon as the carrier drops after a page.
Set Alert — Sets the alert the scanner uses when it receives an alert.
• Alert 1 - 9 — scroll to select the alert tone pattern, The scanner sounds
each alert as you scroll to its numbered value.
• Off — the scanner does not sound an alert.
UB356ZH.fm Page 106 Wednesday, December 19, 2007 11:28 AM