4. Use figure 4 to conduct wind speed measurement , it shows wind flow direction,
but bear in mind Warning do not use it in opposite. A screw can fix on it.
(Note: UNI-T will not provide this screw to the customer, the customer need to buy it
separately)
5. Wait for 2 seconds to obtain a more precise reading during the connection
between wind speed measurement and wind source.
6. Obtain a more precise reading; you should move the anemoscope on at least
20 angle degrees in order to get more accuracy.
7. When the measurement of wind speed and wind temperature in parallel, the
secondary display show wind temperature value.
8. Press " / " (button 6) to conduct temperature unit selection, namely,
Centigrade Temperature and Fahrenheit Temperature.
9. The primary display show wind speed measurement value