Model UT60D: OPERATING MANUAL Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols Measurement Ranges A. Selecting a Measurement Range B. Manual Ranging and Autoranging Measurement Operation A. AC & DC Voltage Measurement B. Measuring Continuity, Diodes & Resistance C. Frequency & Revolution (RPM) Measurement D.
Model UT60D: OPERATING MANUAL Accuracy Specifications A. AC Voltage B. DC Voltage C. Continuity, Diodes & Resistance Test D. Frequency E. Revolution (RPM) F. DC Current G. AC Current Maintenance A. General Service B. Testing the Fuses C. Replacing the Battery D. Replacing the Fuses RS232C Serial Port A. RS232C Port Cable B. Setting of RS232C Serial Ports C.
Model UT60D: OPERATING MANUAL Overview This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes strictly. Warning To avoid electric shock or personal injury, read the "Safety Information" and "Rules for Safe Operation" carefully before using the Meter. Digital Multimeter Model UT60D (hereafter referred to as "the Meter") has autorange and manual range options with maximum reading 3400.
Model UT60D: OPERATING MANUAL Unpacking Inspection Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part: Item 1 2 3 4 5 Description Operating Manual Test Lead 9V Battery (NEDA1604, 6F22 or 006P) (installed) RS232C Interface Cable CD-ROM (Installation Guide & Computer Interface Software) Qty 1 piece 1 pair 1 piece 1 piece 1 piece In the event you find any missing or damage, please contact your dealer immediately.
Model UT60D: OPERATING MANUAL Safety Information This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage category (CAT. III 1000V, CAT. IV 600V) and double insulation. CAT. III: Distribution level, fixed installation, with smaller transient overvoltages than CAT. IV CAT IV: Primary supply level, overhead lines, cable systems etc. Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired.
Model UT60D: OPERATING MANUAL Rules For Safe Operation (1) Warning To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, adhere to the following rules: l l l l l l l l Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors.
Model UT60D: OPERATING MANUAL Rules For Safe Operation (2) l l l l l l l l l l l Disconnect circuit power and discharge all highvoltage capacitors before testing continuity, diodes, resistance or current. Before measuring current, check the Meter’s fuses and turn off power to the circuit before connecting the Meter to the circuit. Replace the battery as soon as the battery indicator appears.
Model UT60D: OPERATING MANUAL International Electrical Symbols AC (Alternating Current) DC (Direct Current) AC or DC Grounding Double Insulated Deficiency of Built-In Battery. Continuity Test. Diode. Fuse. Warning. Refer to the Operating Manual. Conforms to Standards of European Union.
Model UT60D: OPERATING MANUAL The Meter Structure (see figure 1) (figure 1) 1 2 3 4 5 6 7 LCD Display Functional Buttons Rotary Switch HzV Input Terminal: Input for voltage, frequency/rpm, resistance, diode and continuity measurements. COM Input Terminal: Return terminal for all measurements. AmA Input Terminal: Input for 0.1 A to 340.0mA current measurements. 10A Input Terminal: Input for 0.01A to 10.00A current measurements.
Model UT60D: OPERATING MANUAL Rotary Switch Below table indicated for information about the rotary switch positions. Rotary Switch Function Position OFF Power is turned off V DC voltage measurement range from 340.0mV to 1000V or Hz AC voltage measurement range from 3.400V to 750.0V. Continuity test. Diode test. Resistance measurement range from 340.0 to 34.00M . Frequency measurement range from HzRPM 3.400KHz to 34.00MHz or RPM measurement. AC or DC current measurement A range from 340.0 A to 3400 A.
Model UT60D: OPERATING MANUAL Functional Buttons (1) Below table indicated for information about the functional button operations. Button Measuring Operation Performed Function Display Press once to turn the Display Backlight Backlight on and it shall shut off automatically in 10 seconds later. V Switches between AC and DC Hz voltage; the Meter beeps. DC is default. Switches between continuity and (BLUE) diode and resistance measurements; the Meter beeps. Resistance is default.
Model UT60D: OPERATING MANUAL Functional Buttons (2) At OFF Press Hz button while turning on position the Meter to disable Sleep Mode feature. RANGE Any rotary 1. Press RANGE to enter the manual ranging mode; the Meter switch beeps. position except at Manually selecting a range causes the Meter to exit the Hold , mode. and A mode. 2. Press RANGE to step through the ranges available for the selected function; the Meter beeps. 3.
Model UT60D: OPERATING MANUAL Display Symbols (1) (see figure 2) 8 7 3 4 6 9 , 10 5 13 2 1 11 , 12 OLOL 14 15 16 17 (figure 2) Number Symbol Meaning AC Indicator for AC voltage or current. 1 The displayed value is the mean value. DC Indicator for DC voltage or current. 2 The Meter is in the auto range 3 mode in which the Meter automatically selects the range with the best resolution. RS232C Data output is in progress. 4 Data hold is active. 5 The battery is low.
Model UT60D: OPERATING MANUAL Display Symbols (2) (see figure 2) 9 10 11 12 13 14 15 16 17 ,k , M : Ohm. The unit of resistance. : kilohm. 1 x 103 or 1000 ohms. : Megaohm. 1 x 106 or 1,000,000 ohms. Hz, kHz, Hz : Hertz. The unit of frequency MHz in cycles/second. kHz : Kilohertz. 1 x 103 or 1,000 hertz. MHz: Megahertz. 1 x 106 or 1,000,000 hertz. V, mV V : Volts. The unit of voltage. mV : Millivolt. 1 x 10-3 or 0.001 volts. A, mA, A : Amperes (amps). The unit of current. A mA : Milliamp.
Model UT60D: OPERATING MANUAL Measurement Ranges (1) A measurement range determines the highest value the Meter can measure. Most Meter functions have more than one range. See "Accuracy Specifications." A. Selecting a Measurement Range Being in the right measurement range is important: l l If the range is too low for the input, the Meter displays to indicate an overload. If the range is too high, the Meter will not display the most accurate measurement. B.
Model UT60D: OPERATING MANUAL Measurement Ranges (2) 2. To exit the manual range mode, press and hold RANGE for over one second. The Meter returns to the autorange mode and is displayed. Note l If you manually change the measurement range after entering Hold mode, the Meter exits this mode. l Under diode, continuity and A range measurement, only manual range mode is available.
Model UT60D: OPERATING MANUAL Measurement Operation (1) A. AC & DC Voltage Measurement Warning To avoid harms to you or damages to the Meter from electric shock, please do not attempt to measure voltages higher thanDC1000V / AC750V rms, although readings may be obtained. AC Voltage Measurement (see figure 3) red black (figure 3) The AC voltage ranges are: 3.400V, 34.00V, 340.0V and 750.0V. To measure AC Voltage, connect the Meter as follows: 1. 2. 3.
Model UT60D: OPERATING MANUAL Measurement Operation (2) l When AC voltage measurement has been completed, disconnect the connection between the testing leads and the circuit under test. DC Voltage Measurement (see figure 4) red black (figure 4) The DC Voltage ranges are: 340.0mV, 3.400V, 34.00V, 340.0V and 1000V. To measure DC voltage, connect the Meter as follows: 1. 2. 3. Insert the red test lead into the HzV terminal and the black test lead into the COM terminal.
Model UT60D: OPERATING MANUAL Measurement Operation (3) B. Measuring Continuity, Diodes & Resistance Warning To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before measuring continuity, diodes & resistance. Testing for Continuity (see figure 5) W red black (figure 5) To test for continuity, connect the Meter as below: 1. 2. 3. Insert the red test lead into the HzV terminal and the black test lead into the COM terminal.
Model UT60D: OPERATING MANUAL Measurement Operation (4) Testing Diodes (see figure 6) W red black (figure 6) Use the diode test to check diodes, transistors, and other semiconductor devices. The diode test sends a current through the semiconductor junction, then measures the voltage drop across the junction. A good silicon junction drops between 0.5V and 0.8V. To test a diode out of a circuit, connect the Meter as follows: 1. 2. 3.
Model UT60D: OPERATING MANUAL Measurement Operation (5) l l l l Connect the test leads to the proper terminals as said above to avoid error display. The LCD will display indicating open-circuit for wrong connection. The unit of diode is Volt (V), displaying the positiveconnection voltage-drop value. When diode testing has been completed, disconnect the connection between the testing leads and the circuit under test.
Model UT60D: OPERATING MANUAL Measurement Operation (6) Note l The test leads can add 0.1 to 0.2 of error to resistance measurement. To obtain precision readings in low-resistance measurement, that is the range of 340.0 , short-circuit the input terminals beforehand and record the reading obtained (called this reading as X). (X) is the additional resistance from the test lead. Then use the equation: measured resistance value (Y) - (X) = precision readings of resistance.
Model UT60D: OPERATING MANUAL Measurement Operation (7) The frequency measurement ranges are :3.4kHz, 34kHz, 340kHz, 3.4MHz, 34MHz. To measure frequency, connect the Meter as follows: 1. 2. 3. 4. Insert the red test lead into the HzV terminal and the black test lead into the COM terminal. Set the rotary switch to HzRPM; frequency measurement (Hz) is default or press Hz to select Hz measurement mode when it is under V Hz, A Hz, mA Hz or Hz A range.
Model UT60D: OPERATING MANUAL Measurement Operation (8) D. DC or AC Current Measurement (see figure 9) black red (figure 9) Warning Never attempt an in-circuit current measurement where the open-circuit voltage between the circuit and ground is greater than 250V. If the fuse burns out during measurement, the Meter may be damaged or the operator himself may be hurt. Use proper terminals, function, and range for the measurement.
Model UT60D: OPERATING MANUAL Measurement Operation (9) 3. 4. 5. 6. Set the rotary switch to A Hz, mA Hz or Hz A. Use the 10A terminal and Hz A measurement position if the current value to be tested is an unknown. The Meter defaults to DC current measurement mode. To toggle between DC and AC current measurement function, press BLUE button. AC current is displayed as an mean value (calibrated against sine wave effective value). Break the current path to be tested.
Model UT60D: OPERATING MANUAL Turning on the Display Backlight Warning In order to avoid the hazard arising from mistaken readings in insufficient light or poor vision, please use Display Backlight function. l l Press once to turn the Display Backlight on. Display Backlight will automatically shut off in about 10 seconds later. The BLUE button It uses for selecting the required measurement function when there is more than one function at one position of the rotary switch.
Model UT60D: OPERATING MANUAL Operation of Hold Mode Warning To avoid possibility of electric shock, do not use Hold mode to determine if circuits are without power. The Hold mode will not capture unstable or noisy readings. The Hold mode is applicable to all measurement functions. l Press HOLD H to enter Hold mode; the Meter beeps. l Press HOLD H again or RANGE or turn the rotary switch to exit Hold mode; the Meter beeps. l In Hold mode, is displayed.
Model UT60D: OPERATING MANUAL Analogue Bar Graph Display The analogue bar graph likes the needle in a traditional analogue meter (AMM). It refreshes 10 times a sec, which is much faster than that of digital display and is applied to zero adjustment and observation of rapidly changing signal that make digital display hard to read.
Model UT60D: OPERATING MANUAL General Specifications l Maximum Voltage between any Terminals and Grounding l Fused Protection for µAmA Input Terminal : 1000V rms. l : 10A,250V fast type Glass fuse, 5x20mm Fused Protection for 10A Input Terminal l Maximum Display l l l l l l l l l l l l l l l : 0.5A,250V fast type Glass fuse, 5x20mm : Display: 3400 and 34 segments analogue bar graph. Measurement Speed : Updates 3 times /second. o o o o Temperature: Operating : 0 C~40 C (32 F ~104 F).
Model UT60D: OPERATING MANUAL Accuracy Specifications (1) Accuracy: (a% reading + b digits), guarantee for 1 year. o o Operating temperature: 23 C 5 C. Relative humidity: <75%. o Temperature coefficient: 0.1 x (specified accuracy) / 1 C. A. AC Voltage Range Resolution Accuracy (1.5%+3) 3.4V 1mV [lf the signal frequency being 34V 10mV 340V 100mV measured 10kHz,accuracy: 4%+4 750V 1V (2.5%+3) Remarks: l Input impedance 10M . l Displays effective value of sine wave (mean value response).
Model UT60D: OPERATING MANUAL Accuracy Specifications (2) C. Continuity, Diodes & Resistance Test Range Resolution Continuity Test (340.0 ) Diode 1mV 340 0.1 3.4k 34k 340k 3.4M 34M 1 10 100 1k 10k Accuracy Approximate 50 N/A (1.2%+2)+sh ort circuit resistance 0.1 Overload Protection 600Vp (1%+2) (1.2%+2) (1.5%+2) Remarks: l Continuity Test 340.0 Range: Buzzer beeps continuously. Open circuit voltage approximate 1.2V. l Diode Range: Open circuit voltage approximate 2.8V.
Model UT60D: OPERATING MANUAL Accuracy Specifications (3) D. Frequency Range Resolution Accuracy Overload Protection 3.4kHz 1Hz 34kHz 10Hz 600Vp (0.2%+2) 340kHz 100Hz 3.4MHz 1kHz 34MHz 10kHz Remarks: l 100mV Input amplitude 30V rms. l At voltage and current range (VAHz): Range Accuracy 10Hz~1kHz (2%+3) Input amplitude: 1000 digits. E. Revolution (RPM) Range Resolution Accuracy Overload Protection 34k 0.01k 340k 0.1k 600Vp (0.2%+2) 3.4M 1k 34M 10k 340M 100k Remark: l 100mV Input amplitude 32 30V rms.
Model UT60D: OPERATING MANUAL Accuracy Specifications (4) F. DC Current Range Resolution Accuracy Overload Protection 340 A 0.1 A 0.5A, 250V, fast type 3400 A 1 A (1.2%+2) Glass fuse, 5x20 mm. 34mA 10 A 340mA 100 A 10A 10mA (1.5%+2) 10A, 250V, fast type Glass fuse, 5x20 mm. Remark: l 10A Range: For continuous measurement 10 seconds and interval time between 2 measurements greater than 15 minutes. G. AC Current Range Resolution Accuracy Overload Protection 340 A 0.1 A 0.
Model UT60D: OPERATING MANUAL Maintenance (1) This section provides basic maintenance information including battery and fuse replacement instruction. Warning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information. To avoid electrical shock or damage to the Meter, do not get water inside the case. A. General Service l l l l Periodically wipe the case with a damp cloth and mild detergent.
Model UT60D: OPERATING MANUAL Maintenance (2) B. Testing the Fuses Warning To avoid electrical shock or personal injury, remove the test leads and any input signals before replacing the battery or fuse. To prevent damage or injury, install ONLY replacement fuses with identical amperage, voltage, and speed ratings. To test the fuse: 1. 2. Set the rotary switch to and select by pressing BLUE button. Plug a test lead into the terminal HzV and touch the probe tip to the 10A or µAmA terminal.
Model UT60D: OPERATING MANUAL Maintenance (3) C. Replacing the Battery (see figure 10) (figure 10) Warning To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator " " appears. To replace the battery: 1. 2. 3. 4. 5. Turn the Meter to OFF position and remove all connections from the terminals. Remove the screw from the battery compartment, and separate the battery compartment from the case bottom.
Model UT60D: OPERATING MANUAL Maintenance (4) D. Replacing the Fuses (see figure 11) f (figure 11) Warning To avoid electrical shock or arc blast, or personal injury or damage to the Meter, use specified fuses ONLY in accordance with the following procedure. To replace the Meter's fuse: 1. 2. 3. 4. 5. Turn the Meter to OFF position and remove all connections from the terminals. Remove the screw from the battery compartment, and separate the battery compartment from the case bottom.
Model UT60D: OPERATING MANUAL Maintenance (5) 6. Rejoin the battery compartment and the case top, and reinstall the screw. 7. Rejoin the case bottom and case top, and reinstall the 2 screws and 2 rubber feet. Replacement of the fuses is seldom required. Burning of a fuse always results from improper operation. RS232C Serial Port (1) A.
Model UT60D: OPERATING MANUAL RS232C Serial Port (2) C. System Requirements for Installing the UT60D Interface Program To use UT60D Interface Program, you need the following hardware and software: l An IBM PC or equivalent computer with 80486 or higher processor and 640 x 480 pixel or better monitor. l Microsoft Windows 95 or above. l At least 8MB of RAM. l At least 8MB free space in hard drive. l Can access to a local or a network CD-ROM. l A free serial port.
Model UT60D: OPERATING MANUAL 40
Model UT60D: OPERATING MANUAL 41
Model UT60D: OPERATING MANUAL Copyright 2001 Uni-Trend International Limited. All rights reserved. Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITED Address: Dong Fang Da Dao, Bei Shan Dong Fang Industrial Development District, Hu Men Town, Dong Guan City, Guang Dong Province, China Headquarters: Uni-Trend International Limited Address: Rm901, 9/F, Nanyang Plaza 57 Hung To Road Kwun Tong Kowloon, Hong Kong Tel: (852) 2950 9168 Fax: (852) 2950 9303 Email: info@uni-trend.com http://www.uni-trend.