Instructions / Assembly

1. WARNING: TEST THAT POWER IS OFF AT CIRCUIT BREAKER OR
FUSE BLOCK!
2. Determine approximate location (which joists to put it between) and
route cable(s) to joist cavity and fasten cable within 12" of proposed
opening per NEC 334.30 leaving large enough loop to later install box
after finishing floor installation.
3. Determine box location and
drill four 3/4" diameter holes
using template “A” for FB1
series or template “B” for
FB2 series.
Note: When installing tile,
marble or hardwood flooring,
you may want to wait to cut
the opening during the fin-
ished floor installation to
ensure the opening in the
floor does not end up in the
middle of a tile or hardwood
plank.
4. Cut remainder of opening
using the appropriate tem -
plate by connecting the
edges of the holes.
5. Complete the finished floor
installation up to the previ -
ously cut opening, ensuring
the box will still fit into
opening.
6. Pull the wires through the
opening in floor and into the
auto-clamp feature. Knock-
outs are provided for low volt-
age cables if desired. If
Romex-type NM cable is
routed through the knockouts,
an approved wire clamp must
be used.
7. Attach box to flooring using
either the four #6 drywall
screws included or use the
assembled swing brackets.
Tighten screws firmly. When
assembling to carpet, the car-
pet may need to be trimmed
back to ensure the box flange
sets flush. Trim only the car-
pet loops/shag and leave the
carpet backing under the
flange for security. Cut the
padding back 1-2" larger than
the opening to ensure the
device seats firmly and flush
to the floor.
8. Install device(s) per appropriate
installation instructions below.
FB-1 & FB-2 SERIES
TAMPER-RESISTANT FLOOR BOX
INSTALLATION INSTRUCTIONS
NOTICE: READ BEFORE INSTALLING DEVICE
NEW/OLD CONSTRUCTION
FEATURES AND BENEFITS
3
2
4
6
NOTICE: For installation only by a electrician or other qualified
person in accordance with the National Electrical Code, Canadian
Electrical Code, local Codes and the instructions on this sheet.
CAUTION: RISK OF ELECTRICAL SHOCK. Turn off all power to
circuit before installing this device. Improper wiring of any electrical
device can cause serious injury or death.
CAUTION: Connect only copper or copper-clad wire to the device in
this package. Do not connect aluminum wire to this device.
NOTE: USE ONLY ELECTRICAL MOUNTING BOX PROVIDED.
P/N 340907
P.O. Box 4822, Syracuse, NY 13221-4822 • www.passandseymour.com (800-223-4185) Printed in USA
-
-
-
-
Ø
Ø
All FB*TR floor boxes include P&S 15A 125V Tamper-Resistant
Receptacles
Meets NEC Section 406.11 requiring tamper-resistant receptacles
in dwellings.
Complete line of low voltage connectors available thru P&S
Installs before or after the floor is completed to ensure the best
possible finish
Easy rectangular floor cut out
Swing bracket mounting option, superior for tile or marble floors
No messy caulking needed to meet scrub water requirements
Plastic Boxes do not require ground bonding in most applications
INSTALLATION INSTRUCTIONS
This device should be installed in accordance with all appropriate codes
and standards. Warning: Turn off power to outlet box, using breaker or
fuse at service entrance. Verify that power has been removed by testing
with a circuit tester at the outlet box. Caution: This device is for use with
copper or copper-clad wire only.
A. After removing power as described above, use strip gauge on back of
outlet to strip all wires to desired length.
B. Attach wires according to the following diagram. Be sure the wires are
fastened securely either by the terminal screws or through the
speed-wire holes in the back of the outlet. Loosely fastened wires may
result in outlet failure and/or fire hazard. Attach wires using terminal
screws or speed-wire holes: Not both!
C. If using terminal screws: Terminal screws accept up to #12 AWG
wire. Loop wires around screws in a counterclockwise fashion. Fasten
terminal screws securely.
D. If using speed-wire holes: Fully insert #14 AWG solid copper wire
only into the speed-wire holes. Do not use speed-wire holes for cir-
cuits greater than 15 amps. If outlet must be removed, insert screw-
driver blade in the release slot and push it toward the front of the out-
let, releasing the wire. Discard the outlet.
E. Use feed through wires only when wiring to another outlet down stream.
F. Mount the outlet to the box by sandwiching the device to the box with the
intermediate sub-plate using provided #6-32 x 3/4" pan head mounting
screws. Note: Orient the Sub-plate to say “THIS SIDE UP”.
G. Place gasket over the box flange.
H. Assemble o-rings to the provided #6-32 x 1" oval head screws and
use these to assemble the cover plate to the box. Torque to
approximately 10 in/lbs ensuring the gasket stays in place under
the cover plate.
This device should be installed in accordance with all appropriate codes
and standards. Warning: Turn off power to outlet box, using breaker or
fuse at service entrance. Verify that power has been removed by testing
with a circuit tester at the outlet box. Caution: This device is for use with
copper or copper-clad wire only.
A. After removing power as described above, use strip gauge on back of
outlet to strip all wires to desired length.
B. Attach wires according to the diagram below. Be sure the wires are
fastened securely by the terminal screws.
Loosely fastened wires may result in outlet failure and/or fire hazard.
Terminal screws accept up to #12 AWG wire. Loop wires around
screws in a counterclockwise fashion. Fasten terminal screws securely.
C. Mount the outlet in box by
screw ing the strap directly
to the box using provided
#6-32 x 3/4" pan head
mounting screws.
D. Place the shell over the
single receptacle.
E. Place gasket over the box
flange.
F. Assemble o-rings to the
provided #6-32 x 1" oval
head screws and use these
to assemble the cover
plate to the box. Torque to
10 in/lbs ensuring the gas-
ket stays in place under
the cover plate.
TAMPER-RESISTANT DUPLEX RECEPTACLE(S)
B
F
F
F
F
H
H
G
H
G
H
B
C
F
F
E
TAMPER-RESISTANT SINGLE RECEPTACLE
DATACOM KEYSTONE TWO & FOUR PORT
KEYSTONE JACKS
A. See the instructions enclosed with the product for specific wiring.
B. Mount the device in box by sand wiching the device to the box with the
intermediate sub-plate using provided #6-32 x 3/4" pan head mount-
ing screws. Note: Orient the Sub-plate to say “THIS SIDE UP”. For the
two port, attach the device to the box by screwing the strap directly to the
box using provided #6-32 x 3/4" pan head mounting screws.
C. Place gasket over the box flange.
D. Assemble o-rings to the provided #6-32 x 1" oval head screws and
use these to assemble the cover plate to the box. Torque to 10 in/lbs
ensuring the gasket stays in place under the cover plate.
COMBO RECEPTACLE/KEYSTONE
This device should be installed in accordance with all appropriate codes
and standards. Warning: Turn off power to outlet box, using breaker or
fuse at service entrance. Verify that power has been removed by testing
with a circuit tester at the outlet box. Caution: This device is for use with
copper or copper-clad wire only.
A. After removing power as described above, use strip gauge on back of
outlet to strip all wires to desired length.
B. Attach wires according to the diagram below. The terminal screws
accept up to #12 AWG wire. Loop wires around screws in a counter-
clockwise fashion. Fasten terminal screws securely. Loosely fastened
wires may result in outlet failure and/or fire hazard.
C. Ensure divider is in place in box to separate high voltage from low volt-
age. WARNING: FAILURE TO INSTALL DIVIDER CAN CAUSE FIRE,
SERIOUS INJURY OR DEATH.
D. Assemble the desired Keystone Jack to the strap and wire per the
instructions enclosed with the product.
E. Attach the device to the box by screwing the strap directly to the box
using provided #6-32 x 3/4" pan head mounting screws. Note: Orient
the Sub-plate to say “THIS SIDE UP”.
F. Place gasket over the box flange.
G. Assemble o-rings to the provided #6-32 x 1" oval head screws and
use these to assemble the cover plate to the box. Torque to 10 in/lbs
ensuring the gasket stays in place under the cover plate.
D
D
C
B
D
D
C
B
B
B
G
G
F
E
E
C
E
E
G
G
F
C
D
D
C
B
B
7