Datasheet

-Vin
+Vin
+Vout
-Vout
TRIM
3
4 8
7
5
LOAD
UP DOWN TRIMPOT
VR
VR
20K
2:1 wide input range
4:1 wide input range(option)
1000VDC I/O isolation
Built-in EMI filter
Trimming output( 10%)
Remote ON-OFF control
Protections: Short circuit / Overload
Cooling by free air convection
Six-sided shield metal case
Epoxy encapsulated
100% burn-in test
Approvals: FCC / CE
2 years warranty
SPECIFICATION
FileName:DKA30-SPEC 2012-07-18
DKA30A-05 DKA30B-05 DKA30C-05 DKA30A-12 DKA30B-12 DKA30C-12 DKA30A-15 DKA30B-15 DKA30C-15
ORDERNO.
DCVOLTAGE
CURRENTRANGE
RATEDPOWER
OUTPUT
SWITCHINGFREQUENCY
EXTERNAL TRIM Adj.RANGE
VOLTAGERANGE
EFFICIENCY (Typ.)
DCCURRENT
INPUT
ENVIRONMENT
SAFETY &
EMC
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
WEIGHT
FILTER
PROTECTION
RIPPLE&NOISE(max.) Note.2
LINEREGULATION Note.3
LOADREGULATION Note.4
VOLTAGE ACCURACY
A:9~18VDCB:18~36VDCC:36~72VDC
10%
100KHzmin.
2.0%
0.5%
0.5%
100mVp-p
25W 30W 30W
250~ 2500mA 125~ 1250mA 100~ 1000mA
5V 12V 15V
80% 83% 83%
A:3.2A B:1.5A C:0.77A
A:40mA B:20mA C:10mA
I/P-O/P:1KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
100Khrs min. MIL-HDBK-217F (25 )
-40 ~ +85 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
-40 ~ +105 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
50.8*50.8*21.0mm or 2"*2"*0.82" inch (L*W*H)
110g
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
80%
Fullload
Noload
Pinetwork
80% 80% 81% 80% 81%
MechanicalSpecification
Unit:mm(inch)
PinConfiguration
ExternalOutputTrimming
DeratingCurve
Output Output
8765
5.8(0.23)
14 3 2
BOTTOM
VIEW
21(0.82)
SIDE
VIEW
50.8(2.00)
30.48(1.20)
15.24(0.60)
22.9(0.90)
50.8(2.00)
2.5(0.10)
45.72(1.80)
12.7(0.50)
R.C +Vout
NoPin
COM
-Vin -Vout
+Vin TRIM
PinNo. PinNo.
1 5
2 6
3 7
4 8
Features :
OVERLOAD
SHORTCIRCUIT
110~250% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Alloutputequippedwithshortcircuit
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
1.0 +0.2/-0.1
Ta( )
LOAD(%)
-40 0 25 50
71
85
80
100
100
25~30WDC-DCDualOutputConverter
DKA 3 0 series
(Note.5)
CompliancetoEN55022ClassB,FCCpart15ClassB
CompliancetoEN61000-4-2,3,4,5,6,8,lightindustrylevel,criteria A
PROTECTION
Fuserecommended
REMOTECONTROL
Poweron:R.C~-Vin>4.5~5.5VDCoropen,Poweroff:R.C~-Vin<0.8VDCorshort
EMCIMMUNITY
EMCEMISSION

Summary of content (1 pages)