SDS

Product name: Cylindrical Nickel Cadmium Battery Cell
Establishment / Revision: June 17, 2015
4.FIRST-AID MEASURES
Internal cell materials of an opened battery cell
Inhalation :
Cover the victim in a blanket, move to the place of fresh air and keep quiet. Seek medical attention
immediately. When dyspnea (breathing difficulty) or asphyxia (breath-hold), give artificial respiration
immediately.
Skin contact :
Remove contaminated clothes and shoes immediately. Wash the adherence or contact region with soap
and plenty of water. Seek medical attention immediately.
Eye contact :
Immediately flush eyes with water continuously for at least 15 minutes. Seek medical attention
immediately.
A battery cell and internal cell materials of an opened battery cell
Ingestion :
Do not induce vomiting. Seek medical attention immediately.
5.FIRE-FIGHTING MEASURE
Although a battery cell is not flammability, in case of fire, move it to the safe place quickly.
The following measures are taken when it cannot be moved.
Suitable extinguishing media: Dry sand, chemical powder fire extinguishing medium.
Specific hazards: Acrid or harmful fume is emitted during fire.
Special protective equipment for firefighters : Protective
equipment written in Section 8.
6.ACCIDENTAL RELEASE MEASURES
Internal
cell materials, such as electrolyte leaked from battery cell, are carefully dealt with according to the
followings.
Personal precautions :
Forbid unauthorized person to enter. Remove leaked materials with protective equipment written in
Section 8.
Environmental precautions: Do not throw out into the environment.
Method of
recovery and neutralization :
Dilute the leaked electrolyte with water and neutralize with diluted sulfuric acid. The leaked solid is
moved to a container. The leaked place is fully flushed with water.
7.HANDLING AND STORAGE
Handling
Technical measures
Prevention of user exposure: Not necessary under normal use.
Prevention of fire and explosion: Not necessary under normal use.
Precaution for safe handling: Do not damage or remove the external tube.
Specific safe handling advice: Never throw out cells in a fire or expose to high temperatures. Do not
soak cells in water and seawater. Do not expose to strong oxidizers. Do not give a strong mechanical
shock or throw down. Never disassemble, modify or deform. Do not connect the positive terminal to
the negative terminal with electrically conductive material. In the case of charging, use only dedi
cated
charger or charge according to the conditions specified by Sanyo.
Storage
Technical measures
Storage conditions (suitable to be avoided): Avoid direct sunlight, high temperature, high humidity.
Store in cool place (temperature : -30 ~ 35 degree C, humidity : 45 ~ 85%).
Incompatible products: Conductive materials, water, seawater, strong oxidizers and strong acids
Packing material (recommended, not suitable): Insulative and tear-proof materials are recommended.
2