User Manual Ball Valve Servo BVSZWU Technology for Humanity Ubitech Ltd. Page: 1 Version: 1.0.
Date:04-MAY-2020 INDEX 1. INTRODUCTIONS 1.1 1.2 2. KEY & INDICATORS BEHAVIOR 6.1 6.2 6.3 FEATURES & SPECIFICATIONS 2.1 2.2 2.3 3. 6. Custos BVS What’s Z-Wave Physical Specifications Hardware Specifications Software Specifications 7. 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 8. WHAT INSIDE IN THE BOX 5. UNDERSTANDING CUSTOS BVS 5.1 5.2 Ubitech Ltd. 9. Page: 2 Keylock Enable Keylock Disable SETUP Z-WAVE NETWORK 10.1 10.2 10.3 10.
Date:04-MAY-2020 11. WATER VALVE OPERATION 11.1 11.2 11.3 11.4 11.5 12. Forced-calibration Valve Position Turn Valve To OPEN Turn Valve To CLOSE Pause OPEN/CLOSE Operation Resume OPEN/CLOSE Operation WATER LEAK ALARM 12.1 Water Leak Detection & Alarm 12.2 Water Leak Alarm Cancellation 13. TEMPERATURE SENSOR REPORT 13.1 14. Temperature Report APPENDIX 14.1 14.2 14.3 14.4 14.5 14.6 14.7 Ubitech Ltd.
1 INTRODUCTION 1.1 What’s Z-Wave Z-Wave is international wireless protocol used for Smart Home. It’s a mash network technology to ensure reliable twoway communication with each other. Z-Wave provides interoperability and security from multivendor to make sure Certificated product works within any same Z-Wave network. 1.2 Custos BVS Custos Ball Valve Servo “Custos BVS” is capable for outdoor deployment for controlling quarter run water valve OPEN / CLOSE.
Date:04-MAY-2020 2 FEATURES & SPECIFICATIONS 2.1 Physical Specifications Parameter Value Model No. Dimensions Weight Body Color Knob Color Waterproof and Dustproof Usage Operation Temperature Relative Humidity BVS-ZWU (US) / BVS-ZWE (EU) 14.8 x 9.6 x 13.3mm BVS Unit: 603g White Blue IP66 level / Outdoor deployment For Indoor and Outdoor Water Valve On/Off 14~122° F (-10 ~ +50°C) 8% ~ 80% 2.
Date:04-MAY-2020 2.3 Software Specifications Parameter Value Wireless Technology Z-Wave Z-Wave Certification Type Z-Wave Plus v2 Certification Z-Wave SDK Version v7.13.
Date:04-MAY-2020 3 Z-WAVE SOFTWARE DEFINITIONS 3.1 Z-Wave Plus Info Z-Wave Plus Version Role Type Node Type Installer Icon Type User Icon Type 3.
Date:04-MAY-2020 3.4 Notification CC Notification Type Heat Alarm 0x04 Water Alarm 0x05 Water Valve 0x0F 3.
Date:04-MAY-2020 3.7 Association Group Info (AGI) Association Group 1 Name Lifeline Node Count 5 Function - - - 2 Water Valve 5 3 Leak Sensor 5 4 Overheat Alarm 5 - 5 Freeze Alarm 5 - - Ubitech Ltd. Device Reset Locally Notification Basic Report Binary Switch Report Indicator Report Sensor Multilevel Report – Temperature “Auto report based on Configuration Parameter 0x22 Setting.
Date:04-MAY-2020 3.8 Supported Command Classes In NIF Command Class Version ZWAVEPLUS_INFO SWITCH_BINARY ASSOCIATION MULTI_CHANNEL_ASSOCIATION ASSOCIATION_GRP_INFO NOTIFICATION TRANSPORT_SERVICE VERSION MANUFACTURER_SPECIFIC DEVICE_RESET_LOCALLY INDICATOR POWERLEVEL SECURITY SECURITY_2 SUPERVISION FIRMWARE_UPDATE_MD SENSOR_MULTILEVEL - Temperature CONFIGURATION APPLICATION STATUS 2 2 3 4 3 8 2 3 2 1 3 1 1 1 1 5 11 4 1 Ubitech Ltd.
Date:04-MAY-2020 3.9 Configuration CC Note: No Bulk Support equals to True. It will return an Application Rejected Request Command when receiving Configuration Bulk Set or Get (if received without Supervision encapsulation). It will reset all its configuration parameters if either manually reset to factory default or receives a Configuration Default Reset Command. It will NOT modify or reset any configuration parameter when being included or excluded of a Z-Wave network Water Valve - 1 Parameter No.
Date:04-MAY-2020 Water Valve - 2 Parameter No.
Date:04-MAY-2020 Temperature Sensor – 2 Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Ubitech Ltd.
Date:04-MAY-2020 Temperature Sensor – 3 Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Ubitech Ltd.
Date:04-MAY-2020 Temperature Sensor – 4 Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Ubitech Ltd.
Date:04-MAY-2020 Temperature Sensor – 5 Parameter No. Name Info Properties Description Ubitech Ltd.
Date:04-MAY-2020 Water Leak Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Ubitech Ltd.
Date:04-MAY-2020 User Interface Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Ubitech Ltd.
Date:04-MAY-2020 Notification Report Parameter No. Name Info Properties Description Ubitech Ltd.
Date:04-MAY-2020 4 WHAT INSIDE IN THE BOX Standard Custos BVS package comes with below items A. B. C. Custos BVS Main Unit x 1 AC-DC Adaptor x 1, (AC 110/220V to DC 12V/1A) Local Leak Sensor Probe x 1 (Optional) B A Ubitech Ltd. Page: 20 C Version: 1.0.
Date:04-MAY-2020 5 UNDERSTANDING CUSTOS BVS 5.
Date:04-MAY-2020 5.2 Smart Start Labeling BVS comes with PIN Code, DSK string and QR Code for Smart Start and they’re located as below - PIN Code with QR Code on BVS’s housing. 12345 - DSK String with QR Code on Packing, the first 5 digits is PIN code for Smart Start use. 12345-xxxxx-xxxxx-xxxxxxxxxx-xxxxx-xxxxx-xxxxx Ubitech Ltd. Page: 22 Version: 1.0.
Date:04-MAY-2020 6 KEY & INDICATORS BEHAVIOR 6.1 Touch Sense Button - Short Press: One click comes with one short beep sound. - Long Hold: Press and holding the key. “Come with 1 x short beep per second” 6.2 Visual Indicator - 3 Colors LED: GREEN, YELLOW & RED - ON Event: ON, quick blinking and slow blinking 6.3 Sound Indicator - Buzzer: Long & short beep sound. Ubitech Ltd. Page: 23 Version: 1.0.
Date:04-MAY-2020 7 PHYSICAL INSTALLATION 7.1 Quick Installation Instruction: - Make sure to disconnected the power. Place the Valve Handle in Close position. Choose right size Fork of BVS and aligning with Valve Handle. *Refer to “Figure A” Make sure the Knob and Valve Handle are facing on same side. *Refer to “Figure B” Tighten Clamps while holding down the Custos BVS. Unplug the Dust Cover and plug Local Water Sensor Probe into connector tightly.
Date:04-MAY-2020 8 WORKING MODE SUPPORT 8.1 Standalone - Support Water Valve Operation, Water Leak detection & Alarm, Inclusion, Exclusion and Factory Default Reset. By default, Custos BVS is in Standalone Mode with Factory Default Setting and it’s not belonged to any Z-Wave Mesh Network. End user can enjoy all regular functions without Z-Wave benefit. Such as Water Valve, Leak detection by Local Leak Sensor Probe. 8.
Date:04-MAY-2020 9 TOUCH SENSE BUTTON KEYLOCK Custos BVS is capable for outdoor deployment. To prevent mis-operation by rain drop, end-user can enable Touch Sense Button Keylock function. 9.1 Touch Sense Button Keylock Enable After enabled Touch Sense Button Keylock function, Custos BVS will not accept any key event excepting Touch Sense Button Keylock Disable function. (Refer to 9.2) i. Start: Long hold Touch Sense Button 3 seconds then short click 3 times. ii.
Date:04-MAY-2020 10 SETUP Z-WAVE NETWORK 10.1 Check Custos BVS Status: i. Before Adding into Z-Wave Network, you have to make sure Custos BVS is in Standalone mode. ii. By default, Custos BVS does not belong to any Z-Wave Network and color indicator is keeping in Yellow Blinking. *If not, please perform “Factory Default Reset - refer to 10.4” or “Remove from Z-Wave Network – refer to 10.3” 10.
Date:04-MAY-2020 10.4 Factory Default Reset: To remove Custos BVS without involve gateway in Exclusion / Remove device operation and BVS will reset all setting to Factory Default Setting. i. Start: Long hold Touch Sense Button for 10 seconds then short click 5 times. ii. Processing: Yellow LED ON 1 second then wait 2-5 seconds. iii. Success: Green LED on 2 second with long beep sounds for 2 seconds. *Factory Default Reset will: a. Remote the BVS from Z-Wave Network; b. Delete the association setting; c.
Date:04-MAY-2020 11 WATER VALVE OPERATION 11.1 Manual Calibration Valve Position Calibration function will identify the correct OPEN/CLOSE position and torque force, it will avoid excess stress applied to your valve. By default, BVS will perform Auto-calibration when power on. i. Start: Long Hold Touch Sense Button 5 seconds then short click 5 times. ii. Processing: Water Valve run OPEN and CLOSE 1-2 cycles, Yellow LED blinking and quick short beep sound keep continue. iii.
Date:04-MAY-2020 11.5 Resume OPEN/CLOSE Operation Resume only take effect during Pause operation. i. Start: Short click Touch Sense Button once. ii. Finished: Valve resume to operation (Continue to Opening / Closing) and LED indicator changes to LED blinking. Ubitech Ltd. Page: 30 Version: 1.0.
Date:04-MAY-2020 12 Water Leak Sensor & Alarm 12.1 Water Leak Detection & Alarm Custos BVS comes with Local Leak Sensor Probe and support following functions, in short, once Water Leak is detected, Water Leak Alarm will be activated, hence the water valve will be closed spontaneously, at this moment all other operations will not be accepted except Water Leak Alarm Cancellation. i. Activated Water Leak Alarm - RED LED fast blinking. - Fast beep sound. ii. CLOSE Water Valve automatically iii.
Date:04-MAY-2020 13 Temperature Sensor 13.1 Temperature Report i. By default, Custos BVS will send report to Gateway automatically in 1 °C or 4°F change of ambient temperature. ii. Custos will send out °F in US version and °C for other versions. Ubitech Ltd. Page: 32 Version: 1.0.
Date:04-MAY-2020 14 APPENDIX Terminology, all events and operations details including action key event, LED and Buzzer status. 14.1 Z-Wave Terminology Z-Wave Functionality Documentation Terminology Description Inclusion Add The process of adding a node to Z-Wave Network Exclusion Remove The process of removing a node from Z-Wave Network 14.2 System Event Status Event Detail LED Buzzer 2 beep sounds System Ready Standalone mode heartbeat BVS is Ready to operate after power on or reset.
Date:04-MAY-2020 14.3 Touch Sense Button Keylock Event Action / Status Enable Lock Key Function Keylock Enable Success – “In Mesh Network Mode” Success – “In Standalone Mode” Disable Lock Key Function Keylock Disable Success – “In Mesh Network Mode” Success – “In Standalone Mode” 14.
Date:04-MAY-2020 14.5 Network Operation Event Action / Status 1. 2. Smart Start 3. 4. 5. Manual INCLUSION EXCLUSION Firmware Upgrade (OTA) Factory Reset “Device Reset Locally” Ubitech Ltd.
Date:04-MAY-2020 14.
Date:04-MAY-2020 14.7 Water Leak Event & Alarm Event Action / Status Leak Sensor Probe Triggered Start Water Leak Alarm Processing – Close Water Valve automatically Alarm Cancellation Leak Alarm Cancellation Success cancellation Next status – “In Network Mode” Key Action ----Long hold 2 seconds ----- Next status – “In Standalone Mode” Ubitech Ltd.
Date:04-MAY-2020 FCC Statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.