Installation Sheet
- 14 -
3.9 Anti-peep Keypad
The lock supports up to 16-digit Vague Code. Just enter any
16-digit code, as long as a correct code is included in what you
entered, you can open the door.
1:
2:
3:
1 2 3 4 5 6
X X X X X X
1 2 3 4 5 6
X X X X X X
1 2 3 4 5 6
X X X X X X
Example
User Code: 123456
Vague Code
3.10 Place Finger
1. Your nger should cover Fingerprint Reader completely with
some pressure, touching the surrounding metal ring.
2. Make sure that your nger and Fingerprint Reader are clean
and dry. For Fingerprint Reader, use a clean, lint-free cloth to
wipe o any dirt or debris.
3. Please scan multiple ngerprint angles when you register
your ngerprint.
4. While scanning your nger, you shouldn't tap too quickly or
move your nger around.
5. If you have trouble enrolling one nger, try another.
6. U-Bolt Pro ngerprint sensor has self-study function which
the verication rate will be improved after multiple success .
Bottom View Top View Side View
Disable
Please keep Bolt unlocked and press "0" button for 3 seconds
until LED turns green and "0" button blinks.
This can also be set in U-tec App and Auto Lock timing can be
programmed between 10 seconds to 5 minutes. Factory Default
timing is 30 seconds.
ENGLISHENGLISH