QUICK START GUIDE DISPENSERS • CDE224C (115v) • 4 Tap Coffee 30661_C
QUICK START GUIDE USER GUIDE u-line.com u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and inspired innovations — paying close attention to even the smallest details. Applications include residential, outdoor, ADA height compliant, marine, and commercial.
QUICK START GUIDE u-line.com This Quick Start Guide covers the basics of installation and general use of your product. CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Door Swing 5 Door Adjustments 6 General Installation 8 Control Operation 16 First Use 16 Airflow & Product Loading 19 Cleaning 19 Warranty 22 For more details, see the complete User Guide & Service Manual on u-line.
QUICK START GUIDE USER GUIDE u-line.com u-line.com Safety and Warning NOTICE ! DANGER Please read all instructions before installing, operating, or servicing the appliance. Service must be done by factory authorized service personnel. Any parts shall be replaced Use this appliance for its intended purpose only and follow with like components.
QUICK START GUIDE 16-1/2" 90° Door Swing Environmental Requirements 16-1/2" 90° Door Swing u-line.com NOTICE Stainless Black and White Models Electrical installation mustModels observe all state and local codes. This unit requires connection to a This model is intended for indoor/interior applications only 2115WC Models grounded (three-prong), polarized receptacle and is not to be used in installations that are open/ Wallbeen placed by a qualified Wall electrician.
QUICK START GUIDE u-line.com Door Adjustments REVERSING THE DOOR HINGE COVER Location of the unit may make it desirable to mount the door on the opposite side of the cabinet. Hinge cover included with the literature bag is optional. The hinge hardware will be removed and reinstalled on the opposite side of the cabinet. To install hinge cover: 1. Press hinge cover squarely over hinge.
QUICK START GUIDE 1. u-line.com Install top hinge and door: Remove door by tilting forward and lifting door off bottom hinge. Retain shoulder washers; they will be reused. 2. Use a Philips screwdriver to remove hinge pin and reinstall on the opposite surface of the hinge. 3. Remove three screws from hinge holes on the opposite side. Reinstall into holes where the hinge was removed. Take care not to scratch cabinet. Remove bottom hinge: 1. Remove bottom hinge from cabinet using a 1/4” socket. 1.
QUICKGUIDE START GUIDE USER u-line.com u-line.com General Installation The following components are shipped inside the unit: 1. Quad tower (faucets, handles, & hardware) 2. Nitrogen hoses (connecting hardware) 3. Infuser regulators (mounting hardware) 4. Liquid jumper hoses (with in-line filters) and gas jumper hoses 5. Drip tray 6. Cleaning solution (2-ounce packet) (Additional cleaner, ULACOFFEECLEAN, is available at u-line.com) 7. Four casters (2 locking, 2 non-locking) 8.
USER GUIDE QUICK START GUIDE u-line.com u-line.com Connect Hoses to Tower 2. (a) then place foam rubber gasket on top - align holes (b). Make all the hose connections to the tower prior to installing tower onto refrigerator. 1. Install adapter plate to unit with 4 long screws and nuts a b Attach gas jumper hoses - line up and press in firmly. Note: The connectors at the ends of the gas jumper hoses are narrower to correspond with the connections in the tower. 3. 2.
USER QUICKGUIDE START GUIDE u-line.com u-line.com Install Tower on Countertop (See template on next page) Note: These instructions are designed for a standard 36" countertop application. Note: For a customized fit, it may be necessary to acquire screws that are sized to the thickness of your countertop. 1. Position refrigerator under countertop to determine the desired depth. 2. Use the dimensions from Diagram A to determine the center point of the tower mounting hole. 3.
USER GUIDE QUICK START GUIDE u-line.com u-line.com Template for Countertop Installation Note: Verify template has printed true to scale - double check hole dimensions and placement.
USER QUICKGUIDE START GUIDE u-line.com u-line.com Connecting Internal Nitrogen Source 3. Attach nitrogen hose to ball valve on tank regulator. Make sure valve is in the off position - turned clockwise as far as it can go. 4. Attach other end of nitrogen hose to T- connector on gas hose that goes to each infuser regulator. Install Infuser Regulators To Tap Tower 1. Align each infuser regulator with pre-drilled holes in upper left/right of each side wall. Use 2 screws to attach each regulator.
USER GUIDE QUICK START GUIDE u-line.com u-line.com Connect nitrogen to keg 1. Connect keg to tower 1. Attach gas hoses to elbow connectors on infuser regulators - line up and press in firmly. Attach black couplers of the liquid jumper hoses to keg. With your thumb press down on the top of the coupler while pulling up on collar. Press coupler down firmly onto "out" valve. Release collar - listen for a click. Pull up on the coupler to ensure it is locked down. Out Valve 2.
USER GUIDE QUICK START GUIDE u-line.com u-line.com Connecting External Nitrogen Source 4. Insert gasket ring into hole that corresponds to the drilled-out hole in bulkhead and apply food-grade lubricant to inside of gasket ring. 5. Inside cabinet push nitrogen hose through drilled-out hole. Note: Connection to an external Nitrogen source requires drilling one hole through the preinstalled bulkhead located near the top of the back wall. This will allow a grommet sized to .453" hose to fit.
QUICK START GUIDE USER GUIDE u-line.com u-line.com Connections When complete, the connections should look like this: Infuser Regulators Filter Assembly Keg Filter Assembly Keg LEVELING INFORMATION 1. 2. 3. ! CAUTION Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. To comply with applicable federal, state, and local codes, it may be necessary to caulk the refrigerator to the floor. CASTERS (optional) If the unit is not level, shim as needed.
QUICK START GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press Unit will turn On or OFF Adjust Temperature Press or Toggle between ºF / ºC Hold and and hold for 5 seconds When the display is flashing, press and release to adjust the set point temperature. for 5 seconds The display will change units First Use 2. Lift up on pressure Initial startup requires no adjustments.
QUICK START GUIDE u-line.com Set Nitrogen Pressure 5. The pressure should be set around 20 - 30 PSI. Start at 25 PSI on regulated gauge; 7 PSI at infuser regulator. 1. Make sure red regulator valve is in the OFF position. 2. On top of Nitrogen tank, turn black handle counterclockwise until it stops. 3. Rotate the red regulator valve to ON Position; turn counterclockwise 1/4 turn until it stops Unlock 6. 4.
QUICK START GUIDE u-line.com Dispensing Coffee The left tap delivers still cold brew which is refreshing and less acidic than hot coffee. The right tap delivers nitrogen-infused coffee which is the ultimate cold brew experience. Thousands of micro-nitrogen bubbles are infused as the coffee is dispensed. This creates a naturally slightly sweet taste and thicker and smoother texture. Troubleshooting ISSUE No/reduced liquid flow through faucet(s).
3 Do not clean with steel wool pads. QUICK START GUIDE 4 Do not use stainless steel cleaners or polishes on any glass surfaces. u-line.com 5 Clean any glass surfaces with a non-chlorine glass cleaner. Airflow and Product Loading Do not use cleaners not specifically intended for AIRFLOW includes glass, tile, and counter cleaners).
n r. d 2. Spray surface 3. Wait 20 minutes 2 Dampen a non-abrasive cloth with isopropyl alcohol and QUICK START GUIDE wipe down surface 4. 5. u-line.com Dry surface with a clean dry non-abrasive cloth Unscented Bleach and Water USER GUIDE 1. Cleaning Solution Preparation Cleaning Solution Preparation Follow safety instructions on packet. Follow safety instructions on packet. Mix Create a solution of 1 tablespoon of unscented bleach ULACOFFEECLEAN potable with 2water.
QUICK START GUIDE USER GUIDE u-line.com u-line.com DEFROSTING Under normal conditions this unit does not require manual defrosting. Minor frost on the rear wall or visible through the evaporator plate vents is normal and will melt during each cycle. If there is excessive build-up of 1/4” (6 mm) or more, manually defrost the unit. Ensure the door is closing and sealing properly. High ambient temperature and excessive humidity can also produce frost.
U-Line Corporation (U-Line) Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.