QUICK START GUIDE Combo® Models • 115 V / 60 Hz
QUICK START GUIDE u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine use.
QUICK START GUIDE u-line.com This Quick Start Guide covers the basics of installation and general use of your product. For more details, see the complete User Guide & Service Manual on u-line.com.
QUICK START GUIDE u-line.com Safety and Warning Environmental Requirements NOTICE This model is intended for indoor/interior applications only and is not to be used in installations that are open/ Please read all instructions before installing, exposed to natural elements. operating, or servicing the appliance. This unit is designed to operate between 50°F (10°C) and Use this appliance for its intended purpose only and follow 100°F (38°C).
QUICK START GUIDE u-line.com Electrical Water Hookup PREPARE PLUMBING ! WARNING The water valve uses a standard 1/4" (6.35 mm) compression fitting. U-Line recommends using accessory SHOCK HAZARD — Electrical Grounding water hook up kit – part # WATERHOOKUP. The kit Required. Never attempt to repair or perform includes a 10' (3 m) braided flexible water supply line and maintenance on the unit until the electricity has a brass hose fitting. When using a 1/4" (6.35 mm) O.D. been disconnected.
QUICK START GUIDE u-line.com 3. Locate water valve inlet. ! CAUTION Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home. Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket. The gasket provides an adequate seal – other materials could cause blockage of the valve. 4.
QUICK START GUIDE u-line.com Integrated models require 1/4" (6 mm) clearance if 9. Install retaining clip. installed next to a wall. Allow for additional space for any knobs or pulls installed on the integrated panel/frame. BI95/BI98 All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 1/4" (6 mm) to accommodate the handle if the unit is installed next to a wall. 1/4" Min.
QUICK START GUIDE u-line.com General Installation CRESCENT ICE MAKERS, OUTDOOR SERIES AND ADA15IM MARINE AND BI95/BI98 SERIES LEVELING INFORMATION LEVELING INFORMATION 1. Use a level to confirm the unit is NOTICE level. Level should Because these units do not have leveling legs, it be placed along top is extremely important that they sit on a level edge and side edge surface. If they are not level, the ice mold will as shown. not fill evenly. Use a level to confirm 1 the unit is level.
QUICK START GUIDE u-line.com 2. Pull door gasket out of groove INSTALLATION (top edge of door only). Start in 1. Plug in the power/electrical cord. the middle and pull outward, moving toward the edge. This 2. Gently push the unit into position. Be careful not to may take some force. kink the water supply line or entangle the cord. 3. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top 3.
QUICK START GUIDE u-line.com CO1224F Due to differences in floor construction or 1. Fully open door/drawer. surrounding cabinetry, the panel may not sit flush with the top of the door/drawer. 2. Starting at corner, pull gasket away from door/ Panel Door drawer. 3. Continue to pull gasket free from gasket channel. 9. Secure integrated panel to door/drawer 4. Upon removal, lay gasket Bar Clamp using clamps. A down on a flat surface. robust tape may also be used. U-Line 5.
QUICK START GUIDE u-line.com 13.Be sure the screws force their way past the opening on the gasket channel and sit flush against the bottom of the channel. Integrated Panel Integrated Panel 14.Remove clamps from door/drawer. If panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust panel as necessary. Tighten screws upon completion.
QUICK START GUIDE u-line.com Starting at the corners, re-install the gasket into the seated. This may take some force.Control gasket channel in the frame. Make sure the gasket is fully Operation Not Light Power Used LED Up Down CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS ON/OFF Press and release Unit will immediately turn ON or OFF.
QUICK START GUIDE u-line.com First Use To turn off ice production: Raise the bin arm into All U-Line controls are preset at the factory. Initial startup temperature for ice storage. an upright and locked position. The unit will preserve requires no adjustments. NOTICE NOTICE If not intending to use the ice maker, turn the U-Line recommends allowing the unit to run water supply valve off. It is also important to overnight before loading with product.
QUICK START GUIDE u-line.com Sabbath Mode 1 2 3 4 5 6 7 This unit is Star-K certified and offers a Sabbath mode. Sabbath mode disables system responses to user initiated activities and all external functions, including lighting, display and audible alarms. The unit will still maintain internal temperatures and set points. View a full list of Star-K certified U-Line units at www.star-k.org. To enable Sabbath Mode: 1.
U-Line Corporation (U-Line) Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.