User's Guide

Locations to avoid
DON’T place Smoke Alarms in any of the following areas:
Bathrooms, kitchens, shower rooms, garages or other rooms where the smoke alarm may
be triggered by steam, condensation, normal smoke or fumes. Keep at least 6 metres away
from sources of normal smoke/fumes.
Locate away from very dusty or dirty areas as dust build-up in the chamber can impair
performance. It can also block the insect screen mesh and prevent smoke from entering the
smoke detector chamber.
Do not locate in insect infested areas. Small insects getting into the smoke detector
chamber can cause intermittent alarms.
DON’T place Heat Alarms in any of the following areas:
Bathrooms, shower rooms or other rooms where the unit may be triggered by steam or
condensation.
DON’T place Smoke or Heat Alarms in any of the following areas:
• Places where the normal temperature can exceed 100°F (38°C) or be below 32°F (0°C) (e.g.
attics, furnace rooms, directly above ovens or kettles etc.) as the heat/steam could cause
nuisance alarms.
Near a decorative object, door, light fitting, window moulding etc., that may prevent
smoke or heat from entering the Alarm.
Surfaces that are normally warmer or colder than the rest of the room (e.g. attic hatches).
Temperature differences might stop smoke or heat from reaching the unit.
Next to or directly above heaters or air conditioning vents, windows, wall vents etc. that
can change the direction of airflow.
14