Datasheet
7. Performance specification :
*Insulation
1,000 MӨ or more
Apply 500V DC between protective coating
resistance
and termination for 1 min, then measure
(Sub-clause 4.6)
*Dielectric No evidence of flashover Apply 100V(0402) 300V(0603) & 500V (0805,1206,1210,2010,
withstanding
mechanical damage, arcing or 2512) AC between protective coating
voltage insulation break down and termination for 1 minute (Sub-clause 4.7)
Natural resistance change per temp.
degree centigrade.
1ȍ-10ȍ : ± 400 PPM/͠
R
2-R1
Temperature 11ȍ-100ȍ : ± 200 PPM/͠
x 10
6
(PPM/к)
coefficient >100ȍ : ± 100 PPM/͠
R
1(t2-t1)
R
1: Resistance value at room temperature (t1)
R
2: Resistance value at room temp. plus 100 к (t2)
(Sub-clause 4.8)
Short time Resistance change rate is Permanent resistance change after the
overload
± 5% (2.0% + 0.1Ө) Max.
application of a potential of 2.5 times RCWV
± 1% (1.0% + 0.1Ө) Max.
for 5 seconds
(Sub-clause 4.13)
Thick Film Chip Resistors (Terminal Lead Free)
LimitsCharacteristics
Test Methods
( JIS C 5201-1 )
Distributed by Conrad Electronic SE • Klaus-Conrad-Str. 1 • D-92240 Hirschau
Datasheet
V1_0717_01_en
6