Datasheet

Table Of Contents
5. Characteristic :
Dielectric
No evidence of flashover,
Resistors shall be clamped in the trough
withstanding
mechanical damage, arcing
of a 90° metallic V-block and shall be tested at
voltage
or insulation break down
AC potential respectively for 60 +10/ -0 secs.
(Sub-clause 4.7)
Natural resistance change per temp.
degree centigrade.
R
2-R1
Temperature
<20: ± 400 PPM/к Max.
x10
6
(PPM/к)
coefficient
20: ± 350 PPM/к Max.
R
1(t2-t1)
R
1: Resistance value at room temperature (t1)
R
2: Resistance value at room temp. plus 100 к (t2)
(Sub-clause 4.8)
Resistance change rate is Permanent resistance change after the
Short time
± (5% + 0.05Ө) Max. with no
application of a potential of 2.5 times RCWV
overload evidence of mechanical damage for 5 seconds
(Sub-clause 4.13)
Limits
Characteristics
Cement Fixed Resistors
Test Methods
( JIS C 5201-1 )
Distributed by Conrad Electronic SE • Klaus-Conrad-Str. 1 • D-92240 Hirschau
Datasheet
V1_0717_01_en