Vibration Resistance change rate is
± (1% + 0.05Ω) Max.
55Hz, 3 planes 2hrs each
Total amplitude = 1.5mm
(Sub-clause 4.22)
Load life in
humidity
Resistance change after 1,000 hours
(1.5 hours "on", 0.5 hour "off") at RCWV in
a humidity test chamber controlled at 40
± 2 and 90 to 95 % relative humidity
(Sub-clause 4.24.2.1)
Load life
7.10 Permanent resistance change after
1,000 hours operating at RCWV with duty
cycle of (1.5 hours "on", 0.5 hour "off") at
70± 2 ambient
(Sub-clause 4.25.1)
Resistance to
solvent
No deterioration of protective
coatings and markings
Specimens shall be immersed in a bath of
trichroethane completely for 3 minutes with
ultrasonic
(Sub-clause 4.30)
Pulse overload
Resistance change rate is
± (1% + 0.05Ω) Max. with no
evidence of mechanical damage
Resistance change after 10,000 cycles
(1 sec. "on" , 25 secs. "off" ) at 4 times RCWV
(Sub-clause 5.8)
Normal type ± 1.5 %
R/R
Normal type ± 1.5 %
Resistance value
R/R
Resistance value
Metal Film Fixed Resistors
Characteristics Limits
Test Methods
( JIS C 5201-1 )