Datasheet
5. Characteristics :
Natural resistance change per temp.
degree centigrade.
Temperature
≦ 10 Ω
0 ~ ±350
R
2-R1
coefficient
11Ω ~ 99K 0 ~ -450
x10
6
(PPM/℃)
100K ~ 1M 0 ~ -700
1.1M ~ 10M 0 ~ -1500
R
1(t2-t1)
R
1: Resistance value at room temperature (t1)
R
2: Resistance value at room temp.plus 100℃ (t2)
(Sub-clause 4.8)
Short time
overload
Resistance change rate is
± (1 % + 0.05Ω) Max. with no
evidence of mechanical damage
Permanent resistance change after the
application of a potential of 2.5 times RCWV
for 5 seconds.
(Sub-clause 4.13)
Terminal
strength
No evidence of mechanical
damage.
Direct load :
Resistance to a 2.5 kgs direct load for 10 secs.
in the direction of the longitudinal axis of the
terminal leads.
Twist test :
Terminal leads shall be bent through 90 ° at
a point of about 6mm from the body of the
resistor and shall be rotated through 360°
about the original axis of the bent terminal in
alternating direction for a total of 3 rotations.
(Sub-clause 4.16)
Resis.Range
T.C.R. (PPM/℃)
Coated Type Kit Resistors (CFR)
Characteristics Limits
Test Methods
( JIS C 5201-1 )
Distributed by Conrad Electronic SE • Klaus-Conrad-Str. 1 • D-92240 Hirschau
Datasheet
V1_0717_01_en
4