Datasheet

5. Characteristics :
Must be within the specified The limit of error of measuring apparatus
DC. resistance tolerance shall not exceed allowable range or 1% of
resistance tolerance
(Sub-clause 4.5)
Resistors shall be clamped in the trough of
Insulation Insulation resistance is a 90° metallic V-block or foil method use a metal
resistance 20 M Min foil shall be wrapped closely around the body of
the resistor. After that shall be tested at DC potential
respectively specified in the above list for 60 +10/-0 secs.
(Sub-clause 4.6)
Dielectric No evidence of flashover Resistors shall be clamped in the trough of
withstanding mechanical damage, arcing or a 90° metallic V-block or foil method use a metal
voltage insulation break down foil shall be wrapped closely around the body of
the resistor. After that shall be tested at AC potential
respectively specified in the table 1. for 60 +10/-0 secs.
(Sub-clause 4.7)
Natural resistance change per temp.
degree centigrade.
R
2-R1
Temperature 0.1 ~ 12
x 10
6
(PPM/к)
coefficient 12.1 ~ 100K
R
1(t2-t1)
101K ~ 1M
R
1: Resistance value at room temperature (t1)
1.1M ~ 10M
R
2: Resistance value at room temp. plus 100 кʳʻ̇˅ʼ
(Sub-clause 4.8)
±350
-700
-1500
Resis.Range T.C.R. (PPM/͠)
±200
Metal Oxide Film Fixed Resistors
( JIS C 5201-1 )
Characteristics Limits
Test Methods
Distributed by Conrad Electronic SE • Klaus-Conrad-Str. 1 • D-92240 Hirschau
Datasheet
V1_0717_01_en
3