4.19 Resistance change after continuous
5 cycles for duty cycle specified below:
Resistance change rate is
Step
Temperature Time
Temperature
± (2% + 0.05Ө) Max.
1
-55к ± 3к
30 mins
cycling with no evidence of mechanical 2 Room temp.
10Д15 mins
damage 3
+155к ± 2к
30 mins
4 Room temp.
10Д15 mins
7.9 Resistance change after 1,000 hours
Load life in
Resistance value
ϦR/R
(1.5 hours "on", 0.5 hour "off") at RCWV in
humidity
Less than 100KӨ
± 5 %
˴ʳhumidity chamber controlled at 40 к
100KӨ or more
± 10 %
± 2 к and 90 to 95 % relative humidity
4.25.1 Permanent resistance change after
Resistance value
ϦR/R
1,000 hours operating at RCWV with duty
Load life
Less than 100KӨ
± 5 % cycle of (1.5 hours "on", 0.5 hour "off") at
100KӨ or more
± 10 %
70к ± 2к ambient
Resistance change rate is 4.28 Resistance change after 10,000 cycles
Pulse overload
± (5% + 0.05Ө) Max. with no
(1 second "on", 25 seconds "off" ) at 4 times
evidence of mechanical damage RCWV or the max. pulse overload voltage
4.29 Specimens shall be immersed in a bath of
Resistance to No deterioration of protective trichloroethylene completely for 3 minutes with
solvent coatings and markings ultrasonic
Metal Oxide Film Fixed Resistors
( JIS C 5201-1 )
Characteristics