Installation Instructions

Installation and Commissioning Guide - R2.0
3-2 © 2001 Triton Network Systems, Inc. All Rights Reserved.
3.1 Materials Required
The following items are required for connecting a roof-mounted IFU to building equipment.
:DUQLQJV
Risk of Service Interruption
CAUTION: Ensure the outside optical fiber connectors are environmentally
protected. Failure to do so may cause contamination of the fiber surfaces.
CAUTION: To reduce the risk of fiber optic cable damage, use the following
bend radius guidelines for indoor/outdoor fiber optic cable:
w
Long-term (installed): bend radius is equal to 20 times the diameter of the
cable.
w
Short-term (during installation): bend radius is equal to 10 times the diameter
of the cable.
Risk of Personal Injury from Electrical Shock
DANGER HIGH CURRENT HAZARD: Do not turn on power before reading
Triton Network Systems, Inc.s product documentation. This device has a 48
Vdc (5 amps operating peak per feed) direct current input.
DANGER HIGH CURRENT HAZARD: Ensure that the 48 Vdc power
source is set to the OFF position before beginning the installation procedures for
the Invisible Fiber® unit.
o
IFU power cable
o
Outdoor fiber cable
o
GPI cable (optional)
o
Fiber optic cable connector cleaning supplies
o
Tie-wraps, UV-rated
o
Architecture and engineering drawings from site engineering folder
NOTE: Prior to installing the fiber optic cable, ensure that it has been tested for continuity.