INSTALLATION INSTRUCTIONS
CHANGING MODE OF LOCK OPERATION
Power to Lock (PTL) to Power to Open (PTO) conversion.
Loosen mode change screw two turns with the supplied
2mm hex key.
Factory default setting is Power to Lock (PTL)
Move to required position as shown:
Power to Open Fig. A
Power to Lock Fig. B
Retighten mode change screw firmly.
2
POSITIONING OF STRIKE
Peel backing off adhesive template and centrally locate in the
marked position, lining up both the mark for the door latch front
face (Line 1) and the centre mark of the latch (Line 2).
For a metal door drill two Ø5mm holes (A) 22mm above and
below the ‘x’ mark on the template, for a timber door drill
two Ø3mm holes (B).
Ensure secondary bolt is not within strike cavity.
Hole 'B'
Metal Door Frame Timber Door Frame
Strike
cavity
22mm
22mm
Hole 'A'
Line 1
Line 2
A - Power to Open
(Fail-Secure)
Configuration
B - Power to Lock
(Fail-Safe)
Configuration
4
R
S
T
ICK-
TP0
0
0
Depth of lIp cutout will vary due
outline
S
c
r
ibe
Crack and peel back to stIck
template to face of door frame
O
N
TEMP
L
A
TE
Front face of lock latch
ES200-ES2000
ES9000
to width of door frame and
mounting technIque.
S
T
ICK-
TP0
0
0
Depth of lIp cutout will vary due
outline
S
c
r
ibe
Crack and peel back to stIck
template to face of door frame
O
N
TEMP
L
A
TE
Front face of lock latch
ES200-ES2000
ES9000
to width of door frame and
mounting technIque.
Part No. ES9000-121
30621 1008
Using the template as a guide, mortice out the door frame to the
required size.
Countersink holes in metal frame to accept screws.
For wider framed doors an Extension Lip may be required. Refer
to over leaf for sizes and part numbers.
MORTICING REBATE
3
24mm
To enable the Electric strike to be located in the door frame, first
mark the position of the Door Latch front face on the door frame
with the door in the closed position, ('X ' mm).
Mark where centre of latch meets door frame:
- For new installations, mark frame where front of latch touches
the door frame at the midpoint of the latch bolt.
- For retrofit installations, remove existing strike plate and ensure
that latch fits into and is centred in existing hole.
Frame
Frame
Door
Door
Latch
Mark Door latch
front face on frame
(Line 1).
MARKING OF STRIKE POSITION
1
'X ' mm
'X ' mm
Mark centre of Door
latch on frame
(Line 2).
Line 1
Line 2