Installation Instructions
Have Questions? NOTE: Construction methods are always improving. Please ensure you
1–800–BUYTREX have the most up-to-date installation instructions by visiting: trex.com TEHR-0720
NOTES:
» TREX ENHANCE RAILINGS ARE DESIGNED TO BE INSTALLED OVER THE DECKING FRAME OR ON INSIDE OF RIM JOIST. NOTCHING OF PRESSURE-TREATED
POSTS OR POSTS INSTALLED ON OUTSIDE OF RIM JOIST IS NOT ALLOWED.
» All Enhance Railing lengths are manufactured at CLEAR SPAN dimensions (spanning between space of posts): 72" for 6' clear span. Note that railings are
designed to be slightly longer than required to allow for very slight play in post placement – trimming may be required. IT IS VERY IMPORTANT TO MEASURE
FIRST.
Care and Cleaning
Maintaining the appearance of your Trex Enhance railing is important. Occasional washing is recommended. Over time your railing may show signs
of weathering as a result of exposure to the elements. The frequency of cleaning will depend on the environment and exposure to various types of
elements.
» Clean railing with standard cleaning vinegar or mild soap and water.
» For more detailed cleaning recommendations, please refer to the Trex Railing Care and Cleaning guide found on www.trex.com.
PARTS
A. Top Rail
B. Bottom Rail
C. Brackets
D. Aluminum Round Balusters
E. Adjustable Foot Block
F. Post Sleeve Cap*
G. Post Sleeve Skirt*
H. Post Sleeve**
- 4" x 4" x 48"
I. Trex Decking
J. Trex Fascia
K. Code-approved Wood Joist
- 2" x 8"
L. Code-approved Wood Rim Joist
- 2" x 8" or Larger
* Item not included in the railing kits.
** 4" x 4" post sleeve is designed to fit over 4" x 4"
pressure-treated post. Actual size 4.45" x 4.45" x 48"
Screws Supplied with RSB
C1.
Wood screw for attachment of RSB
to wood post/composite sleeve
C2. Self-drilling screw for
attachment of RSB to rail
F
*
A
B
E
C
H
**
C
G
*
I
J
K
L
D
C1
C2
DETERMINING BALUSTERS NEEDED
Baluster Type Per 6' Section
Horizontal Application 15
HOW TO INSTALL STANDARD HORIZONTAL RAILING
TREX ENHANCE
®
Read all instructions BEFORE installation.
NOTE: Always consult local building codes for approved
post installation.
Important: If using 48" post sleeves, measure carefully to allow
for clearance of both rail attachment as well as clearance for
post cap attachment, and trim these before installing over
pressure treated posts. For 36" railing height, post sleeve
should be cut at minimum of 40".
Installing
Pressure-Treated Posts
»
PLEASE REFER TO LOCAL BUILDING CODE REQUIREMENTS
PRIOR TO ATTACHING PRESSURE TREATED POSTS. ON THE
FOLLOWING PAGE ARE INSTRUCTIONS GUIDELINES FOR
GENERAL REQUIREMENTS.
» Posts are to be installed
6' clear span to
accommodate appropriate
railing length.
» Attach posts using 1/2"
carriage bolts.
» Minimum joist size is 2" x
8".
» Top bolts must be 1" from
tops of joists.
» Bottom bolts must be
5-1/8" from top bolts.
Note:
Blocking MUST be added for extra strength.
1
5-1/8" min.
2" x 8"