Command Name Code Reader Message
RF status display 527 RFST Cx Ox Tx Fxxx Rxx Gxx
Axx I04
C0 = RF controlled by host C1
= RF-by-presence sensor O0 =
RF o
O1 = RF on
T1 = uniqueness timeout of 2
min T2 = uniqueness timeout of
15 sec
T3 = uniqueness timeout of 30
sec
Fxxx = RF output frequency, xxx
= 000 to 118
Rxx = Tag decoder range
(distance) for ATA tags, 00 to 1F
hexadecimal range value
Gxx = Tag decoder range
(distance) for eGo Plus Tags, 00
to 1F hexadecimal range value
Axx = RF power attenuation, 00
max to 0A min (10 dB less than
max)
I04 = fixed
If you enter RF settings
using command #642NN,
the display command for RF
output frequency, F is “Fxx” and
indicates use of the backward-
compatible frequency entry
method.
RF timeout = innite set 693F Done
RF timeout set N = 0–F
(always expired, 4,8,12,20,24,32,
48,60,92,152,300,452,600,752
ms, infinite)
693N Done