Specification
Ceramica
INSTALLATION
SPECIFICATIONS:
HD Installable Yes
Connection Type Self stick tiles
Acclimation Period 48 hours minimum required in room prior to installation
T
emperature Range
65°F to 85°F required in room of installation
A
fter installation temps should stay between 55F to 85F
Interior Product Only Yes. See limitations/exclusions below
Storage Horizontally
Dye Lots Yes. Install from a minimum of 3 to 4 different boxes and dye lots
a
t one time. See page 3 of Owner's Manual for more information
Expansion Space Yes. For room perimeters and fixed objects please leave
1/8" minimum space, 1/4” optimum space
F
loor Flatness Tolerances 1/4" over 10', Use floor leveler when exceeding tolerance
H
and Roller Required Yes
7
5 lb min. Floor Roller No
M
oisture Reading Guidelines; Based on Tramex Concrete Moisture Encounter Plus Meter
OVER CONCRETE (scale 0 to 6%)
Scale 0 to 5% No moisture barrier
Scale 5% to 6% Do not install
Moisture Reading Guidelines; Never use 6 mil poly over wooden subfloors
OVER WOOD
Scale 0 to 13% OK to install. Do not install above 13% moisture levels
Primer Over Wooden Subfloors Yes
Basement Proofer over Concrete Yes
Moisture Barrier (6 mil poly) Yes
Installs Over Radiant Flooring Yes. Electric or hydronic approved — best practice recessed
min 1/2" below finished floor. Do not turn thermostat above 85°F
Suspended Wood Floors Yes. 18" minimum well ventilated crawl space
Use moisture barrier over ground/dirt
Especially for mobile home installations
Foam/Cushioned Underlayment No. Voids warranty if used in any application
Clear Spread Adhesives Yes. If used, adhesive manufacturer warranty prevails for
adhesion, Halstead Warranty for wear layer
Grout Options Optional. Use only - Simple Grout (premixed) by
Custom Building Products. Stocked in stores
Approved Subfloors - See Below Must be smooth, solid, dry and no deflection
Wood Yes. Solid, engineered, parquet
Plywood No OSB or Particleboard
Vinyl Yes, install over 1 layer of vinyl only. Linoleum, VCT, LVT, peel & stick
Concrete Yes. Sealed, unsealed, poured in place gypsum
On grade or below grade (see moisture guidelines)
Tile (Stone) No
Dricore Yes
Subfloors Not Approved Carpet (any type), foam underlayment, cushioned back vinyl,
rubber, cork, laminates
Subfloor Approved Products Primer - Henry 336, Basement Proofer - Custom Building Products
RedGard or TM Basement Proofer, Floor Leveler - Henry 554 &
555 Level Pro
Limitations/Exclusions These types of installations will NOT be covered under warranty:
All exterior installations & seasonal porches, boats/campers/RV's,
sunrooms/solariums, non-temperature controlled rooms or homes
Steam Cleaner DO NOT USE
Vertical Surfaces & Staircases Not covered under warranty. Can be done using high quality
construction adhesive. Product not intended for this usage
Limited Warranties Lifetime residential, lifetime light commercial
During Acclimation & Install