Personal Computer User Manual
2 Troubleshooting Procedures 2.3 Power Supply Troubleshooting
2-10 Satellite Pro M10 Series Maintenance Manual (960-431)
1st Battery
Error code Meaning
20h Main battery overvoltage is detected. (Not supported)
21h Main battery charge current is more than 6.05 A.
22h Main battery discharge current is more than 0.5 A when there is no load.
23h Main battery charge current is more than 4.3 A when DC IN direct charge
is off.
24h Current sensing IC is not normal.
25h Main battery charge current is more than 0.3A when the battery isn't
being charged.
2nd Battery
Error code Meaning
30h 2nd battery overvoltage is detected. (Not supported)
31h 2nd battery charge current is more than 6.05 A.
32h 2nd battery discharge current is more than 0.5 A when there is no load.
33h 2nd battery charge current is more than 3.1 A when DC IN direct charge
is off.
34h Current sensing IC is not normal.
35h 2nd battery charge current is more than 0.3A when the battery isn't being
charged.
S3V output
Error code Meaning
40h S3V voltage is under or equal to 3.14V when the computer is turned on
or off.
45h S3V voltage is under or equal to 3.14V when the computer is booting up.