4.35 Fluorescent Lamp 4 Replacement Procedures
4.35.1 Replacing the 14.1-inch WXGA LG Fluorescent Lamp
CAUTION: When replacing the fluorescent lamp, wear finger covers or gloves to avoid
contaminating or damaging the LCD panel and backlight unit.
Removing the fluorescent lamp
To remove the 14.1-inch WXGA LG fluorescent lamp, follow the steps below and refer to
figures 4-68 to 4-71.
Disassembly of outside tape/Cover shield
1. Disassembly of Tape Adhesive2 used for Top case fixing.
CAUTION: Pressure or stress should not be given on Top case during this process.
2. Disassembly of Cover shield (S)1.
CAUTION: Pressure or stress should not be given on Source PCB. Usage of gloves with
anti-electric discharge coating is recommended to eliminate possible
damage on circuits occurred by ESD.
Figure 4-68 Replacing 14.1-inch LG fluorescent lamp (WXGA) (1)
TECRA M10 Maintenance Manual (960-685) [CONFIDENTIAL] 4-111