Operation Manual

15EN
TOSHIBA RAS-07/10/13UKP (US) 1075000802
Hi POWER operation
When you press the Hi POWER button during cooling or A operation, the air conditioner will start the following
operation.
Cooling operation
Performs the cooling operation lower than the setting temperature.
When the room temperature is above the setting temperature, air flow is directed downward. In addition, fan
speed is high*. Once room temperature is within 1°C of the setting temperature, air flow is returned to its
regular direction to cool the entire room with maximum efficiency.
* Noise level raises in accordance with fan speed.
ECO timer operation
When you press the ECO button during cooling or A operation, the air conditioner will start the following operation.
The fan speed will be automatically controlled.
Cooling operation ( )
In the operation suppression zone, where capacity is kept to the
minimum, overcooling is prevented by raising the temperature
setting by 1°C after 1 hour and by 2°C after 2 hours of operation.
The room temperature is thus regulated between the operation
suppression zone and the set temperature.
Automatic Operation
The air conditioner selects and operates in one of the operating modes of cooling or fan only, depending on
the room temperature.
If the AUTO mode is uncomfortable, you can select the desired conditions manually.
Room temperature in operation
Operating condition
Cooling
operation
Fan only
operation
The set temperature +1°C or higher
(in case that the room is hot )
The set temperature –1°C to +1°C
Performs the cooling operation at a temperature
1°C higher than the setting.
Performs the fan only operation (low speed) while
monitoring the room temperature. When the room
temperature changes, the air conditioner will select
the cooling mode.
HOW THE AIR CONDITIONER WORKS
Operation suppression zone
Operation starts
Set temperature
1 hour
1°C
2 hours
2°C
01RAS-07/10/13UKP P13-19 2/1/02, 12:04 AM15